Evaluation of Self-collected Saliva Samples Without Viral Transport Media for SARS-CoV-2 Testing via RT-PCR and Comparison of Amplicon Sequences Against Commonly Used Primers in Diagnostic Assays
Military Medicine · 2024
DOI: 10.1093/milmed/usae070 ↗Kurz gefasst
Fachartikel in der Zeitschrift Military Medicine, 2024. Verfasst von Benjamin D Ramos und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, 60th Medical Group (MDG), Travis Air Force Base (AFB), Fairfield, CA 94535, USA. Hauptthemen laut MEDLINE: Saliva, SARS-CoV-2, COVID-19, Specimen Handling. Die Arbeit nennt 14 Literaturangaben. Gefördert von: David Grant USAF Medical Center's Clinical Investigation Facility.
Abstract (Originalsprache)
Introduction
Mass screening for SARS-CoV-2 using nasopharyngeal swabs (NPS) is costly, uncomfortable for patients, and increases the chance of virus exposure to health care workers. Therefore, this study focused on determining if self-collected unpreserved saliva can be an effective alternative to NPS collection in COVID-19 surveillance. Materials and Methods In this study, patients being tested for SARS-CoV-2 using NPS were asked to provide a saliva sample to compare their results. NPS samples were evaluated for SARS-CoV-2 using BioFire® FilmArray® Torch® or Cepheid® GeneXpert® systems while saliva samples were evaluated using an in-house developed reverse transcriptase polymerase chain reaction (RT-PCR) which targeted the Envelope (E) and Nucleocapsid (N) genes.
Results
Detection of SARS-CoV-2 using self-collected saliva was found to be only slightly less accurate (<5%) than testing using NPS. In addition, initial saliva RT-PCR identified 27 positive subjects, 18 of which provided amplicons sufficient for confirmatory sequencing. The sequencing data showed a genetic shift in the virus within our population sometime between 22 June and July 8, 2021 from Alpha to Delta variant.
Conclusions
The saliva sample collection method identifies the E gene in SARS COVID-2 samples which provides an alternative specimen source to the NPS. This identifies the S gene and ORF1ab. Saliva collection is more convenient to the patient, yields comparable results to NPS collection, and potentially increases Covid-19 surveillance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Pathology, 60th Medical Group (MDG), Travis Air Force Base (AFB), Fairfield, CA 94535, USA.
- Clinical Investigation Facility, 60MDG, Fairfield, CA 94535, USA.
ORCID-Profile: Andrew R Garcia
Förderung
- David Grant USAF Medical Center's Clinical Investigation Facility
Zitieren
APA
Ramos, B. D., Hudson, N. R., Gonzales, D. E., Brown, A. N., White, M. G., Browde, R. J., McNeary-Garvin, A. M., Knight, C. E., Pham, K. C., Sweatt, R. J., Phan, L. M., Ly, E., & Garcia, A. R. (2024). Evaluation of Self-collected Saliva Samples Without Viral Transport Media for SARS-CoV-2 Testing via RT-PCR and Comparison of Amplicon Sequences Against Commonly Used Primers in Diagnostic Assays. Military Medicine. https://doi.org/10.1093/milmed/usae070
Vancouver
Ramos BD, Hudson NR, Gonzales DE, Brown AN, White MG, Browde RJ, et al. Evaluation of Self-collected Saliva Samples Without Viral Transport Media for SARS-CoV-2 Testing via RT-PCR and Comparison of Amplicon Sequences Against Commonly Used Primers in Diagnostic Assays. Military Medicine. 2024. doi:10.1093/milmed/usae070
BibTeX
@article{Ramos2024,
author = {Ramos, Benjamin D and Hudson, N Ryan and Gonzales, Diane E and Brown, Ashleigh N and White, Matthew G and Browde, Ryan J and McNeary-Garvin, Antoinette M and Knight, Celynn E and Pham, Kevin C and Sweatt, Robert J and Phan, Liem Minh and Ly, Eileen and Garcia, Andrew R},
title = {Evaluation of Self-collected Saliva Samples Without Viral Transport Media for SARS-CoV-2 Testing via RT-PCR and Comparison of Amplicon Sequences Against Commonly Used Primers in Diagnostic Assays},
journal = {Military Medicine},
year = {2024},
doi = {10.1093/milmed/usae070}
}