Comparison between RT-PCR and TMA for SARS-CoV-2 detection and proposal of a diagnostic algorithm based on cut-off values
Enfermedades infecciosas y microbiologia clinica (English ed.) · 2026
DOI: 10.1016/j.eimce.2026.503068 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Enfermedades infecciosas y microbiologia clinica (English ed.), 2026. Verfasst von Albert Bernet Sánchez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Microbiology Section, Hospital Universitari Arnau de Vilanova [Arnau de Vilanova University Hospital], Lleida, Spain; Institut de Recerca Biomèdica […. Hauptthemen laut MEDLINE: Algorithms, SARS-CoV-2, COVID-19, COVID-19 Nucleic Acid Testing. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: SARS-CoV-2 caused a pandemic with more than 778 million cases and 7 million deaths. The high diagnostic demand forced laboratories to incorporate new techniques, such as transcription-mediated amplification (TMA). This study compares TMA with RT-PCR in routine clinical samples and evaluates the relationship between relative light units (RLU) and RT-PCR results to define possible cut-off ranges. METHODS: A prospective study was carried out over 1 year in the microbiology laboratory of Arnau de Vilanova University Hospital in Lleida. All samples for SARS-CoV-2 were processed using TMA (Aptima Hologic), and a portion was analyzed in parallel with RT-PCR (LightMix®, GeneXpert®, or Cobas®). Concordance between techniques, sensitivity, and specificity were calculated. RT-PCR was considered the reference technique. RESULTS: A total of 15,156 samples were analyzed with both techniques. Concordance was substantial (κ = 0.692), with a sensitivity of 97.89% and a specificity of 64.74%. Of the results, 11.28% corresponded to false positives and 8.44% to false negatives for TMA. RLU values between 350 and 559, considered negative by the TMA system, were positive by RT-PCR in 20.56%. In intermediate RLU values (560-899), the probability of having a negative RT-PCR was around 50%, dropping to 3.78% for values between 1000 and 1099. CONCLUSIONS: These results support the use of TMA as a screening method, provided the positivity threshold is lowered to 350 RLU and positive cases are confirmed by RT-PCR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Microbiology Section, Hospital Universitari Arnau de Vilanova [Arnau de Vilanova University Hospital], Lleida, Spain; Institut de Recerca Biomèdica [Biomedical Research Institute] - Fundació Dr. Pifarré, IRBLleida, Llei…
- Microbiology Section, Hospital Universitari Arnau de Vilanova [Arnau de Vilanova University Hospital], Lleida, Spain.
Zitieren
APA
Bernet Sánchez, A., Bellés Bellés, A., López González, E., Prats Sanchez, I., Mormeneo Bayo, S., Riesgo Magaña, M., & García González, M. (2026). Comparison between RT-PCR and TMA for SARS-CoV-2 detection and proposal of a diagnostic algorithm based on cut-off values. Enfermedades infecciosas y microbiologia clinica (English ed.). https://doi.org/10.1016/j.eimce.2026.503068
Vancouver
Bernet Sánchez A, Bellés Bellés A, López González E, Prats Sanchez I, Mormeneo Bayo S, Riesgo Magaña M, et al. Comparison between RT-PCR and TMA for SARS-CoV-2 detection and proposal of a diagnostic algorithm based on cut-off values. Enfermedades infecciosas y microbiologia clinica (English ed.). 2026. doi:10.1016/j.eimce.2026.503068
BibTeX
@article{BernetSnchez2026,
author = {Bernet Sánchez, Albert and Bellés Bellés, Alba and López González, Eric and Prats Sanchez, Iván and Mormeneo Bayo, Saray and Riesgo Magaña, María and García González, Mercè},
title = {Comparison between RT-PCR and TMA for SARS-CoV-2 detection and proposal of a diagnostic algorithm based on cut-off values},
journal = {Enfermedades infecciosas y microbiologia clinica (English ed.)},
year = {2026},
doi = {10.1016/j.eimce.2026.503068}
}
EUVIMED