Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation
International Journal of Computer Assisted Radiology and Surgery · 2025
DOI: 10.1007/s11548-025-03471-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2025. Verfasst von Bo Zhang und 12 weiteren Autor:innen. Beteiligte Einrichtung: WuXi AMIT Intelligent Medical Technology Col., Ltd., Wuxi, 214000, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Punctures, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Traditional surgical robot system relying on computed tomography (CT) navigation suffers from two drawbacks during abdominal organ puncture surgeries. Firstly, the puncture target is displaced under the influence of respiration, thereby reducing the puncture accuracy. Secondly, the puncture process lacks real-time visualization, which may potentially give rise to medical accidents. This paper presents a semi-automatic surgical robot system based on the fusion guidance of real-time ultrasound images and CT, along with the monitoring of the patient’s respiratory state, to address these issues.
Method
This system utilizes a six-axis force sensor in contact with the human body, and a respiratory model can be constructed through data got from force sensor to monitor the patient’s respiratory phase and recommend the optimal puncture phase. The issue of non-real-time puncture guidance is addressed through the real-time registration and fusion of ultrasound (US) images with preoperative CT images.
Results
Phantom experiments and animal experiments were carried out based on this design. The test results indicate that in these two experiments, the average fusion error between US and CT of the main tissues in the liver is within 3 mm. For puncture accuracy, in the phantom experiment, the average puncture error was 1.0 mm, with a minimum of 0 mm and a maximum of 2.1 mm. In the animal experiment, the average puncture error was 2.5 mm, ranging from a minimum of 1.6 mm to a maximum of 3.0 mm.
Conclusion
The results of two experiments show both the image fusion accuracy and puncture accuracy of this system are within 3mm, which can meet the requirement of 5 mm puncture accuracy in clinical practice. Approximately 70% of the operation are automatically accomplished by robot system, greatly reducing the reliance on the doctor’s experience.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- WuXi AMIT Intelligent Medical Technology Col., Ltd., Wuxi, 214000, China.
- Future Robotics Organization, Waseda University, Tokyo, 1620044, Japan.
- WuXi AMIT Intelligent Medical Technology Col., Ltd., Wuxi, 214000, China. chenkui@amit.net.cn.
- The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510000, China.
- Tianjin University Central Hospital, Tianjing, 300000, China. dr.jingxiang@aliyun.com.
- Faculty of Science and Engineering, Waseda University, Tokyo, 1698555, Japan.
Zitieren
APA
Zhang, B., Chen, K., Yao, Y., Wu, B., Li, Q., Zhang, Z., Fan, P., Wang, W., Lin, M., Jing, X., Sugano, S., Fujie, M. G., & Kuang, M. (2025). Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-025-03471-5
Vancouver
Zhang B, Chen K, Yao Y, Wu B, Li Q, Zhang Z, et al. Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation. International Journal of Computer Assisted Radiology and Surgery. 2025. doi:10.1007/s11548-025-03471-5
BibTeX
@article{Zhang2025,
author = {Zhang, Bo and Chen, Kui and Yao, Yuhang and Wu, Bo and Li, Qiang and Zhang, Zheming and Fan, Peihua and Wang, Wei and Lin, Manxia and Jing, Xiang and Sugano, Shigeki and Fujie, Masakatsu G and Kuang, Ming},
title = {Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2025},
doi = {10.1007/s11548-025-03471-5}
}
EUVIMED