Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Xuesong Dai und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Tianjin University, Tianjin, China. Hauptthemen laut MEDLINE: Brachytherapy, Prostatic Neoplasms, Punctures, Robotic Surgical Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangsu Province for Young Scholars, National Natural Science Foundation of China, Natural Science Research of Jiangsu Higher Education Institutions of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In prostate brachytherapy, oblique‐tip needles are frequently used to deliver radioactive seeds to the target area. These needles often experience deflection during insertion, leading to deviations from the planned trajectory and compromising treatment accuracy.

Method

This study did not involve human participants or animals, and therefore, ethics review and approval were not required. The proposed method combines preoperative needle trajectory planning with real‐time intraoperative corrections, using an adaptive PID controller enhanced by reinforcement learning to adjust corrective forces during needle insertion.

Results

Experimental results demonstrated that the proposed method reduced the average seed implantation error to 1.92 mm, with a standard error of 0.56 mm. These findings indicate that the method minimises needle deflection and improves precision in seed implantation.

Conclusion

The proposed modular robotic system and puncture control method enhance the precision of seed implantation and show promise for improving treatment outcomes in prostate cancer therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyProstatic NeoplasmsPuncturesRobotic Surgical ProceduresRoboticsMaleHumansEquipment DesignNeedlesAlgorithmsProstate

Stichwörter der Autor:innen

controllercorrective forceneedle deflectiontransrectal prostate brachytherapy

Autor:innen und Institutionen

  • School of Mechanical Engineering, Tianjin University, Tianjin, China.
  • Automation College, Wuxi University, Wuxi, China.
  • Key Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin, China.

ORCID-Profile: Xuesong Dai, Yongde Zhang

Förderung

  • Natural Science Foundation of Jiangsu Province for Young Scholars
  • National Natural Science Foundation of China
  • Natural Science Research of Jiangsu Higher Education Institutions of China

Zitieren

APA

Dai, X., Zhang, Y., & Sun, Y. (2025). Research on Prostate Brachytherapy Robot Design and Puncture Control Strategy. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70059

Vancouver

Dai X, Zhang Y, Sun Y. Research on Prostate Brachytherapy Robot Design and Puncture Control Strategy. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70059

BibTeX
@article{Dai2025,
  author = {Dai, Xuesong and Zhang, Yongde and Sun, Yue},
  title = {Research on Prostate Brachytherapy Robot Design and Puncture Control Strategy},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70059}
}
Kostenlos starten →