Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Baoying Peng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Information Science and Technology University, Beijing, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Robotics, Radiotherapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In order to meet the kinematic requirements of large range of motion, payload, and stiffness of Intra‐Operative Radiation Therapy robots, a 6‐degree‐of‐freedom (DOF) parallel platform (Stewart‐Gough mechanism) is introduced and a dimensional synthesis study is carried out.

Methods

The kinematic and static stiffness models of the 6‐DOF parallel robot for Intra‐Operative Radiation Therapy are derived around a virtual isocentric control point. Under the premise of ensuring the positional accuracy, the optimal dimensions of the initial rod length, the radius of the fixed base and movable platform, and the circumferential angle of the 6‐DOF parallel platform are obtained by using the multi‐objective optimization method combining the non‐dominated sorting genetic algorithm and the global 4criterion with the working space, stiffness, and load as the optimization objectives.

Results

A full‐size prototype was built, and experiments on payload, range of motion, modality, and harmonic response were carried out.

Conclusions

The results show that the theoretical stiffness model has high accuracy, and the dimensional synthesised 6‐DOF parallel platform can meet the clinical requirements of Intra‐Operative Radiation Therapy in terms of workspace, stiffness and payload, as well as position accuracy. Trial Registration The equipment in this study has not yet obtained a medical device registration certificate, and the 6‐DOF parallel robot for Intra‐Operative Radiation Therapy experiments were conducted using a self‐developed model, which has not yet been subjected to clinical trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresRoboticsRadiotherapyHumansAlgorithmsEquipment DesignBiomechanical PhenomenaRange of Motion, Articular

Stichwörter der Autor:innen

6‐DOF parallel platformintra‐operative radiation therapymulti‐objective optimizationpayloadstiffness

Autor:innen und Institutionen

  • Beijing Information Science and Technology University, Beijing, China.
  • Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

ORCID-Profile: Yushuo Zhu

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Peng, B., Zhu, Y., & Niu, C. (2025). Dimensional Synthesis of 6‐DOF Parallel Robot for Intra‐Operative Radiation Therapy. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70076

Vancouver

Peng B, Zhu Y, Niu C. Dimensional Synthesis of 6‐DOF Parallel Robot for Intra‐Operative Radiation Therapy. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70076

BibTeX
@article{Peng2025,
  author = {Peng, Baoying and Zhu, Yushuo and Niu, Chuanmeng},
  title = {Dimensional Synthesis of 6‐DOF Parallel Robot for Intra‐Operative Radiation Therapy},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70076}
}
Kostenlos starten →