Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction
The International Journal of Medical Robotics and Computer Assisted Surgery · 2025
DOI: 10.1002/rcs.70119 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Yao Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Control Science Engineering Department, Shandong University, Jinan, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Robotics. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, Young Scholars Program of Shandong University.
Abstract (Originalsprache)
Background
The concentric tube robots (CTRs) show great potential for minimally invasive surgery due to their size and flexibility. However, friction remains a key factor contributing to accuracy errors in CTR applications, and reducing friction effects to enhance CTRs' precision remains a critical challenge.
Methods
This paper pioneers the application of a vibration friction reduction (VFR) method for CTRs, aiming to reduce inter‐tube friction and improve system accuracy. First, a CTR system with VFR was designed, incorporating a vibration generator consisting of four vibration motors and a 3D‐printed component. Then, to better test and analyse the effects of vibration on friction, a variable‐friction coefficient kinematic model for CTRs was established. Finally, experiments were conducted to validate the approach.
Results
The results show that the VFR method can reduce the positional error of CTRs by approximately 36.5%.
Conclusion
This paper provides a new approach to enhance CTRs' accuracy in surgical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Control Science Engineering Department, Shandong University, Jinan, China.
- School of Mechanical Engineering, Shandong University, Jinan, China.
- Engineering Research Center of Intelligent Unmanned System of MOE, Shandong University, Jinan, China.
- Mechanical Engineering Department, Tsinghua University, Beijing, China.
ORCID-Profile: Yao Wang, Fuxin Du, Gang Zhang
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- Young Scholars Program of Shandong University
- National Key Research and Development Program of China
- Shandong Provincial Postdoctoral Innovative Talents Funded Scheme
Zitieren
APA
Wang, Y., Du, F., Zhang, G., Zhang, P., Liu, T., Li, Y., & Song, R. (2025). Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70119
Vancouver
Wang Y, Du F, Zhang G, Zhang P, Liu T, Li Y, et al. Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70119
BibTeX
@article{Wang2025,
author = {Wang, Yao and Du, Fuxin and Zhang, Gang and Zhang, Peng and Liu, Tianxiang and Li, Yibin and Song, Rui},
title = {Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2025},
doi = {10.1002/rcs.70119}
}
EUVIMED