EUVIMEDEUVIMED entdecken
Crossref

Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction

Yao Wang iD, Fuxin Du iD, Gang Zhang iD, Peng Zhang, Tianxiang Liu, Yibin Li, Rui Song

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Yao Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Control Science Engineering Department, Shandong University, Jinan, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Robotics. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, Young Scholars Program of Shandong University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The concentric tube robots (CTRs) show great potential for minimally invasive surgery due to their size and flexibility. However, friction remains a key factor contributing to accuracy errors in CTR applications, and reducing friction effects to enhance CTRs' precision remains a critical challenge.

Methods

This paper pioneers the application of a vibration friction reduction (VFR) method for CTRs, aiming to reduce inter‐tube friction and improve system accuracy. First, a CTR system with VFR was designed, incorporating a vibration generator consisting of four vibration motors and a 3D‐printed component. Then, to better test and analyse the effects of vibration on friction, a variable‐friction coefficient kinematic model for CTRs was established. Finally, experiments were conducted to validate the approach.

Results

The results show that the VFR method can reduce the positional error of CTRs by approximately 36.5%.

Conclusion

This paper provides a new approach to enhance CTRs' accuracy in surgical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresRoboticsVibrationFrictionHumansEquipment DesignMinimally Invasive Surgical ProceduresBiomechanical PhenomenaPrinting, Three-DimensionalReproducibility of Results

Stichwörter der Autor:innen

concentric tube robotsfriction analysismodellingvibration friction reduction

Autor:innen und Institutionen

  • Control Science Engineering Department, Shandong University, Jinan, China.
  • School of Mechanical Engineering, Shandong University, Jinan, China.
  • Engineering Research Center of Intelligent Unmanned System of MOE, Shandong University, Jinan, China.
  • Mechanical Engineering Department, Tsinghua University, Beijing, China.

ORCID-Profile: Yao Wang, Fuxin Du, Gang Zhang

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • Young Scholars Program of Shandong University
  • National Key Research and Development Program of China
  • Shandong Provincial Postdoctoral Innovative Talents Funded Scheme

Zitieren

APA

Wang, Y., Du, F., Zhang, G., Zhang, P., Liu, T., Li, Y., & Song, R. (2025). Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70119

Vancouver

Wang Y, Du F, Zhang G, Zhang P, Liu T, Li Y, et al. Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70119

BibTeX
@article{Wang2025,
  author = {Wang, Yao and Du, Fuxin and Zhang, Gang and Zhang, Peng and Liu, Tianxiang and Li, Yibin and Song, Rui},
  title = {Optimising the Accuracy of Concentric Tube Robots: Using Vibration Friction Reduction},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70119}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche