EUVIMEDEUVIMED entdecken
Crossref

Artifact on MR imaging by a dental magnetic attachment keeper: Preliminary study on a new keeper removable phantom

Ichiro Ogura, Yoshihiro Sugawara, Kazuhiro Nagata, Mitsuhiro Watanabe

Oral Science International · 2019

DOI: 10.1002/osi2.1007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral Science International, 2019. Verfasst von Ichiro Ogura und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Gefördert von: JSPS KAKENHI.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Dental magnetic attachments with satisfactory retentive force and stability are now commercially available for dental treatment. The aim of this study was to investigate a new phantom for evaluation of the artifact on magnetic resonance ( MR ) imaging by a dental magnetic attachment keeper. Material and Methods We developed a new keeper removable phantom for evaluation of the artifact on MR imaging. A keeper was inserted in an acrylic pole in a PET bottle. The keeper from acrylic pole of the phantom was removable. The keeper with saline solution in the PET bottle with a head and neck coil underwent MR imaging at our university hospital. We measured the real size (unit: mm) of artifact of the phantom with the keeper using a DICOM viewer. Furthermore, the size of artifact of a patient's image with the same three keepers in the mouth was measured on the image using the DICOM viewer, too.

Results

In MR images of the phantom with a keeper, the maximum size of artifact on axial T1‐weighted, T2‐weighted and STIR images were 78 mm, 85 mm, and 67 mm, respectively. Regarding MR images of the patient with three keepers, the maximum size of artifact on axial T1‐weighted, T2‐weighted and STIR images were 106 mm, 111 mm and 100 mm, respectively.

Conclusions

We investigated a new keeper removable phantom for evaluation of the artifact on MR imaging. The phantom can be used to evaluate the artifact on MR imaging by a dental magnetic attachment keeper.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Ogura, I., Sugawara, Y., Nagata, K., & Watanabe, M. (2019). Artifact on MR imaging by a dental magnetic attachment keeper: Preliminary study on a new keeper removable phantom. Oral Science International. https://doi.org/10.1002/osi2.1007

Vancouver

Ogura I, Sugawara Y, Nagata K, Watanabe M. Artifact on MR imaging by a dental magnetic attachment keeper: Preliminary study on a new keeper removable phantom. Oral Science International. 2019. doi:10.1002/osi2.1007

BibTeX
@article{Ogura2019,
  author = {Ogura, Ichiro and Sugawara, Yoshihiro and Nagata, Kazuhiro and Watanabe, Mitsuhiro},
  title = {Artifact on MR imaging by a dental magnetic attachment keeper: Preliminary study on a new keeper removable phantom},
  journal = {Oral Science International},
  year = {2019},
  doi = {10.1002/osi2.1007}
}
Kostenlos starten →