Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms
Otolaryngology–Head and Neck Surgery · 2024
DOI: 10.1002/ohn.857 ↗At a glance
Journal article in Otolaryngology–Head and Neck Surgery, 2024. Written by Leyn Shakhtour and 6 co-authors. Institution: Division of Otolaryngology-Head and Neck Surgery, The George Washington University School of Medicine and Health Sciences, Washington, District of Co…. Major MEDLINE topics: Operating Rooms. Cited 5 times so far (Crossref); 16 references.
Abstract (original language)
Objective
Operating room (OR) sounds may surpass noise exposure thresholds and induce hearing loss. Noise intensity emitted by various surgical instruments during common pediatric otolaryngologic procedures were compared at the ear‐level of the surgeon and patient to evaluate the need for quality improvement measures. Study Design Cross‐sectional study.
Setting
Single tertiary care center.
Methods
Noise levels were measured using the RISEPRO Sound Level Meter and SoundMeter X 10.0.4 at the ear level of surgeon and patient every 5 minutes. Operative procedure and instrument type were recorded. Measured noise levels were compared against ambient noise levels and the Apple Watch Noise application.
Results
Two hundred forty‐two total occasions of noise were recorded across 62 surgical cases. Cochlear implantation surgery produces the loudest case at the ear‐level of the patient (91.8 Lq Peak dB; P < .001). The otologic drill was the loudest instrument for the patient (92.1 Lq Peak dB; P < .001), while the powered microdebrider was the loudest instrument for the surgeon (90.7 Lq Peak dB; P = .036). Noise measurements between surgeon and patient were similar ( P < .05). Overall agreement between the Noise application and Sound Level Meter was excellent (intraclass correlation coefficient of 0.8, with a 95% confidence interval ranging from 0.32 to 0.92).
Conclusion
Otolaryngology OR noises can surpass normal safe thresholds. Failure to be aware of this may unwittingly expose providers to noise‐related hearing loss. Mitigation strategies should be employed. Quality improvement measures, including attention to surgical instrument volume settings and periodic decibel measurements with sound applications, can promote long‐term hearing conservation.
Discussion
Otolaryngology OR noises can surpass normal safe thresholds. Failure to be aware of this may unwittingly expose providers to noise‐related hearing loss. The duration, frequency of exposure, and volume levels of noise should be studied further.
Implications for Practice
Mitigation strategies should be employed. Quality improvement measures, including attention to surgical instrument volume settings and periodic decibel measurements with sound applications, can promote long‐term hearing conservation.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Otolaryngology-Head and Neck Surgery, The George Washington University School of Medicine and Health Sciences, Washington, District of Columbia, USA.
- Department of Otolaryngology, Children's National Hospital, Washington, District of Columbia, USA.
- Division of Surgery, Children's National Hospital, Washington, District of Columbia, USA.
ORCID profiles: Leyn Shakhtour, Sophia Song
Cite
APA
Shakhtour, L., Song, S., Orobello, N. C., Ambrose, T., Rana, M. S., Behzadpour, H. K., & Reilly, B. K. (2024). Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.857
Vancouver
Shakhtour L, Song S, Orobello NC, Ambrose T, Rana MS, Behzadpour HK, et al. Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.857
BibTeX
@article{Shakhtour2024,
author = {Shakhtour, Leyn and Song, Sophia and Orobello, Nicklas C and Ambrose, Tracey and Rana, Md Sohel and Behzadpour, Hengameh K and Reilly, Brian K},
title = {Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2024},
doi = {10.1002/ohn.857}
}
EUVIMED