EUVIMEDEUVIMED entdecken
Crossref

Sound levels in the operating theatre resulting from hammering during cementless total hip arthroplasty

Yasuhiro Homma, Tetsuro Wada, Masashi Unoki, Taiji Watari, Tomonori Baba, Atul F Kamath, Muneaki Ishijima

Journal of Orthopaedic Science · 2025

DOI: 10.1016/j.jos.2024.12.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Science, 2025. Verfasst von Yasuhiro Homma und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Ja…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Operating Rooms, Noise, Occupational, Hearing Loss, Noise-Induced. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although hearing loss in orthopaedic surgeons from exposure to hammering sounds have been previously reported, there are no reports on the noise environment during total hip arthroplasty (THA) in Japan. The aim of this study was to investigate the sound level generated by cementless THA in Japan, and to discuss the broader sound environment within this space. METHODS: 94 cementless THAs (94 patients with informed consent) performed by four surgeons were included. The equivalent continuous A-weighted sound levels (LAeq) in a series of 1086 continuous hammering maneuvers without pause and the maximum C-weighted sound levels (LCpeak) in 17,210 hammering sounds were investigated. RESULTS: Among the hammering sounds analysed in terms of LAeq, the sound pressure level associated with some procedures did result in non-scrubbed personnel being exposed to the 8-h sound levels exceeding the LAeq threshold (85 dB), while most procedures exceeded this threshold for scrubbed personnel. For scrubbed personnel, the maximum number of operations that could be safely attended per day were 16.1 and 1.6 operations under average and worst-case scenario conditions, respectively. For LCpeak, no sound was found to be above the threshold (135 dB) for either non-scrubbed or scrubbed personnel. CONCLUSIONS: Although average sound levels in a standard operating theatre during cementless THA did not exceed recommended thresholds among non-scrubbed medical practitioners, our data are not sufficient to conclude that the sound environment is safe for scrubbed personnel close to the sound source. Further investigation is needed regarding sound exposure and the occurrence of hearing impairment in surgeons who perform total hip arthroplasties.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipOperating RoomsNoise, OccupationalHearing Loss, Noise-InducedOccupational ExposureHumansFemaleMaleMiddle AgedAgedJapanAdult

Stichwörter der Autor:innen

Hammering soundHearing lossTotal hip arthroplastyWork-related injury

Autor:innen und Institutionen

  • Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan; Department of Orthopaedics, Faculty of Medicine, Juntendo Univers…
  • Department of Otolaryngology-Head & Neck Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
  • School of Information Science, Japan Advanced Institute of Science and Technology, Ishikawa, Japan.
  • Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Homma, Y., Wada, T., Unoki, M., Watari, T., Baba, T., Kamath, A. F., & Ishijima, M. (2025). Sound levels in the operating theatre resulting from hammering during cementless total hip arthroplasty. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2024.12.007

Vancouver

Homma Y, Wada T, Unoki M, Watari T, Baba T, Kamath AF, et al. Sound levels in the operating theatre resulting from hammering during cementless total hip arthroplasty. Journal of Orthopaedic Science. 2025. doi:10.1016/j.jos.2024.12.007

BibTeX
@article{Homma2025,
  author = {Homma, Yasuhiro and Wada, Tetsuro and Unoki, Masashi and Watari, Taiji and Baba, Tomonori and Kamath, Atul F and Ishijima, Muneaki},
  title = {Sound levels in the operating theatre resulting from hammering during cementless total hip arthroplasty},
  journal = {Journal of Orthopaedic Science},
  year = {2025},
  doi = {10.1016/j.jos.2024.12.007}
}
Kostenlos starten →