Decibels in the operating theatre: a study of noise levels during surgical procedures
ANZ Journal of Surgery · 2024
DOI: 10.1111/ans.19001 ↗Kurz gefasst
Fachartikel in der Zeitschrift ANZ Journal of Surgery, 2024. Verfasst von Joanne Au und 2 weiteren Autor:innen. Beteiligte Einrichtung: Plastic and Reconstructive Surgery, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Noise, Occupational, Operating Rooms, Occupational Exposure, Surgical Instruments. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Background
Exposure to excessive noise volumes is an occupational health and safety risk. Australian guidelines recommend a time weighted exposure maximum of 85 dB (dB) or a maximum peak noise level of up to 140 dB, as chronic and repeated high dB exposure can result in significant hearing impairment. The aim of this study was to assess the volume of noise generated by common surgical instruments while utilizing the National Institute for Occupational Safety and Health (NIOSH) app.
Methods
Sound levels were measured using the NIOSH app. The NIOSH app was used to take equivalent continuous A‐weighted sound levels (L Aeq ) and the C‐weighted peak sound pressure (L Cpeak ) measurements for specific instruments while in use in theatre. A minimum of three readings per instrument were taken at immediate and working distances.
Results
L Aeq measurements ranged from 62.9 to 89.3 dB. The Padgett Dermatome and Frazier Sucker exceeded recommended exposure limits with an averaged L Aeq reading of 85.7 dB(A) and 85.1 dB(A) respectively. L Cpeak readings ranged from 89.9 to 114.7 dB(C) with none of the instruments exceeding a peak sound level beyond the recommended level of 140 dB(C).
Conclusion
The cumulative effect of loud surgical instruments across prolonged or combined operations may result in theatre staff being exposed to hazardous noise levels, impacting the health and wellbeing of staff, staff performance and patient care. Utilization of a phone app can improve the awareness of noise pollution in theatres, thereby empowering staff to be proactive about their health and improvement of their work environment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Plastic and Reconstructive Surgery, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
ORCID-Profile: Joanne Au, Sam Hamilton, Angela Webb
Zitieren
APA
Au, J., Hamilton, S., & Webb, A. (2024). Decibels in the operating theatre: a study of noise levels during surgical procedures. ANZ Journal of Surgery. https://doi.org/10.1111/ans.19001
Vancouver
Au J, Hamilton S, Webb A. Decibels in the operating theatre: a study of noise levels during surgical procedures. ANZ Journal of Surgery. 2024. doi:10.1111/ans.19001
BibTeX
@article{Au2024,
author = {Au, Joanne and Hamilton, Sam and Webb, Angela},
title = {Decibels in the operating theatre: a study of noise levels during surgical procedures},
journal = {ANZ Journal of Surgery},
year = {2024},
doi = {10.1111/ans.19001}
}