EUVIMEDOpdag EUVIMED
Crossref

Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device

Mitali Sakharkar, Parth K Jalihal, Kimberly Ramirez, Faisal Karmali, Richard F Lewis, Divya A Chari

Otolaryngology–Head and Neck Surgery · 2025

DOI: 10.1002/ohn.1148 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, 2025. Written by Mitali Sakharkar and 5 co-authors. Institution: Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA. Major MEDLINE topics: Nystagmus, Optokinetic, Eye-Tracking Technology, Smartphone. Cited 2 times so far (Crossref); 31 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

To develop a proof‐of‐concept smart‐phone‐based eye‐tracking algorithm to assess non‐pathologic optokinetic (OKN) nystagmus in healthy participants. Current videonystagmography (VNG) is typically restricted to in‐office use, and advances in portable vestibular diagnostics would yield immense public health benefits. Study Design Prospective cohort study.

Setting

Tertiary academic medical center.

Methods

Healthy participants (n = 39) without dizziness or vertigo were recruited. A smart‐phone attached to a custom head stabilization device illuminated by a white LED circuit was used to record nystagmus induced with a 30 frames per second OKN stimulus over a 60‐second period. A centroid tracking algorithm was created to detect slow‐phase velocity (SPV) of horizontal nystagmus in a diverse subject cohort in a variety of lighting conditions. Nystagmus recordings were compared to those obtained with a standard VNG system.

Results

Non‐pathologic nystagmus from an OKN stimulus was measured across multiple lighting conditions, with high signal‐to‐noise ratios (SNR) and mean SPV 22.13 ± 5.26°/s. Nystagmus SPV was not significantly different between the device and standard VNG system (t = −0.5, P = .6). Lighting conditions produced SNRs of 57.30 (ideal), 50.59 (backlit), 51.33 (side‐lit), 49.28 (dark), 54.52 (outdoor lighting).

Conclusion

We demonstrate the feasibility of a novel portable oculography system in the detection of non‐pathologic nystagmus in healthy subjects. Future applications of this system include: (1) to obtain real‐time measurements of nystagmus during an acute vertigo attack; (2) to test patients unable or unwilling to present to a specialized vestibular laboratory; (3) to efficiently repeat testing overtime; (4) to improve accessibility of vestibular testing.

Subjects

MeSH terms (MEDLINE)

Nystagmus, OptokineticEye-Tracking TechnologySmartphoneHumansMaleFemaleProspective StudiesAdultHealthy VolunteersAlgorithmsMiddle Aged

Author keywords

eye‐tracking algorithmnystagmussmart‐phonevertigovideonystagmography

Authors and institutions

  • Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Otolaryngology-Head and Neck Surgery, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA.

Cite

APA

Sakharkar, M., Jalihal, P. K., Ramirez, K., Karmali, F., Lewis, R. F., & Chari, D. A. (2025). Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.1148

Vancouver

Sakharkar M, Jalihal PK, Ramirez K, Karmali F, Lewis RF, Chari DA. Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.1148

BibTeX
@article{Sakharkar2025,
  author = {Sakharkar, Mitali and Jalihal, Parth K and Ramirez, Kimberly and Karmali, Faisal and Lewis, Richard F and Chari, Divya A},
  title = {Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2025},
  doi = {10.1002/ohn.1148}
}
Start for free →