EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Analysis of Small Intestinal Motility in 3D Cine‐ MRI Using Centerline‐Aware Motion Estimation

Louis D van Harten iD, Catharina S de Jonge, Femke Struik, Jaap Stoker iD, Ivana Išgum iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29571 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Louis D van Harten und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Intestine, Small, Gastrointestinal Motility, Crohn Disease, Imaging, Three-Dimensional. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Currently available tools for noninvasive motility quantification of the small intestine are limited to dynamic 2D MRI scans, which are limited in their ability to differentiate between types of intestinal motility.

Purpose

To develop a method for quantification and characterization of small intestinal motility in 3D, capable of differentiating motile, non‐motile and peristaltic motion patterns. Study Type Prospective. Subjects Fourteen healthy volunteers (127 small intestinal segments) and 10 patients with Crohn's disease (87 small intestinal segments). Field Strength/Sequence 3.0 T, 3D balanced fast field echo sequence, 1 volume per second. Assessment Using deformable image registration between subsequent volumes, the local velocity within the intestinal lumen was quantified. Average velocity and average absolute velocity along intestinal segments were used with linear classifiers to differentiate motile from non‐motile intestines, as well as erratic motility from peristalsis. The mean absolute velocity of small intestinal content was compared between healthy volunteers and Crohn's disease patients, and the discriminative power of the proposed motility metrics for detecting motility and peristalsis was determined. The consensus of two observers was used as referenced standard. Statistical Tests Student's t ‐test to assess differences between groups; area under the receiver operating characteristic curve (AUC) to assess discriminative ability. P < 0.001 was considered significant.

Results

A significant difference in the absolute velocity of intestinal content between Crohn's patients and healthy volunteers was observed (median [IQR] 1.06 [0.61, 1.56] mm/s vs. 1.84 [1.37, 2.43] mm/s), which was consistent with manual reference annotations of motile activity. The proposed method had a strong discriminative performance for detecting non‐motile intestines (AUC 0.97) and discernible peristalsis (AUC 0.81). Data Conclusion Analysis of 3D cine‐MRI using centerline‐aware motion estimation has the potential to allow noninvasive characterization of small intestinal motility and peristaltic motion in 3D. Evidence Level 3 Technical Efficacy Stage 2

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intestine, SmallGastrointestinal MotilityCrohn DiseaseImaging, Three-DimensionalMagnetic Resonance Imaging, CineHumansMaleFemaleAdultProspective StudiesMotionMiddle AgedPeristalsisYoung AdultHealthy VolunteersReproducibility of ResultsAlgorithmsImage Interpretation, Computer-AssistedImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Crohn's diseasedynamic MRIimage alignmentmotilitysmall intestine

Autor:innen und Institutionen

  • Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Informatics Institute, University of Amsterdam, Amsterdam, The Netherlands.
  • Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam, The Netherlands.

ORCID-Profile: Louis D van Harten, Jaap Stoker, Ivana Išgum

Zitieren

APA

van Harten, L. D., de Jonge, C. S., Struik, F., Stoker, J., & Išgum, I. (2025). Quantitative Analysis of Small Intestinal Motility in 3D Cine‐ MRI Using Centerline‐Aware Motion Estimation. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29571

Vancouver

van Harten LD, de Jonge CS, Struik F, Stoker J, Išgum I. Quantitative Analysis of Small Intestinal Motility in 3D Cine‐ MRI Using Centerline‐Aware Motion Estimation. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29571

BibTeX
@article{vanHarten2025,
  author = {van Harten, Louis D and de Jonge, Catharina S and Struik, Femke and Stoker, Jaap and Išgum, Ivana},
  title = {Quantitative Analysis of Small Intestinal Motility in 3D Cine‐ MRI Using Centerline‐Aware Motion Estimation},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29571}
}
Kostenlos starten →