Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device
Otolaryngology–Head and Neck Surgery · 2025
DOI: 10.1002/ohn.1148 ↗Kurz gefasst
Fachartikel in der Zeitschrift Otolaryngology–Head and Neck Surgery, 2025. Verfasst von Mitali Sakharkar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Nystagmus, Optokinetic, Eye-Tracking Technology, Smartphone. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Objective
To develop a proof‐of‐concept smart‐phone‐based eye‐tracking algorithm to assess non‐pathologic optokinetic (OKN) nystagmus in healthy participants. Current videonystagmography (VNG) is typically restricted to in‐office use, and advances in portable vestibular diagnostics would yield immense public health benefits. Study Design Prospective cohort study.
Setting
Tertiary academic medical center.
Methods
Healthy participants (n = 39) without dizziness or vertigo were recruited. A smart‐phone attached to a custom head stabilization device illuminated by a white LED circuit was used to record nystagmus induced with a 30 frames per second OKN stimulus over a 60‐second period. A centroid tracking algorithm was created to detect slow‐phase velocity (SPV) of horizontal nystagmus in a diverse subject cohort in a variety of lighting conditions. Nystagmus recordings were compared to those obtained with a standard VNG system.
Results
Non‐pathologic nystagmus from an OKN stimulus was measured across multiple lighting conditions, with high signal‐to‐noise ratios (SNR) and mean SPV 22.13 ± 5.26°/s. Nystagmus SPV was not significantly different between the device and standard VNG system (t = −0.5, P = .6). Lighting conditions produced SNRs of 57.30 (ideal), 50.59 (backlit), 51.33 (side‐lit), 49.28 (dark), 54.52 (outdoor lighting).
Conclusion
We demonstrate the feasibility of a novel portable oculography system in the detection of non‐pathologic nystagmus in healthy subjects. Future applications of this system include: (1) to obtain real‐time measurements of nystagmus during an acute vertigo attack; (2) to test patients unable or unwilling to present to a specialized vestibular laboratory; (3) to efficiently repeat testing overtime; (4) to improve accessibility of vestibular testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
- Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA.
- Department of Otolaryngology-Head and Neck Surgery, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA.
Zitieren
APA
Sakharkar, M., Jalihal, P. K., Ramirez, K., Karmali, F., Lewis, R. F., & Chari, D. A. (2025). Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.1148
Vancouver
Sakharkar M, Jalihal PK, Ramirez K, Karmali F, Lewis RF, Chari DA. Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.1148
BibTeX
@article{Sakharkar2025,
author = {Sakharkar, Mitali and Jalihal, Parth K and Ramirez, Kimberly and Karmali, Faisal and Lewis, Richard F and Chari, Divya A},
title = {Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2025},
doi = {10.1002/ohn.1148}
}
EUVIMED