EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging

Zijian Gao, Qianxue Shan, Ziqin Zhou, Ziqiang Yu, Weitian Chen iD

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70331 ↗

At a glance

Journal article in NMR in Biomedicine, published online on 2026-06-17. Written by Zijian Gao and 4 co-authors. Institution: Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong. Major MEDLINE topics: Magnetic Resonance Imaging, Spin Labels. 48 references. The full text is freely available (open access, CC BY 4.0). Funded by: Research Grants Council of the Hong Kong SAR.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Inhomogeneous magnetization transfer (ihMT) is sensitive to dipolar order associated with motion‐restricted macromolecules and can be characterized by the dipolar relaxation time . In this study, we propose a spin‐lock MRI framework for quantification. Specifically, we introduce a ‐sensitive metric, , derived from the distinct relaxation rate , defined as the difference between dual‐frequency and single‐frequency measurements. To enable dual‐frequency spin‐lock acquisition, we developed a dedicated rotary‐echo spin‐lock sequence. Based on this framework, we further estimated and the macromolecular proton fraction (MPF) within a unified acquisition. The proposed method was evaluated using numerical simulations, phantom experiments, and in vivo imaging in the healthy human brain. Simulations demonstrated high sensitivity of to and supported the robustness of the proposed approach under the investigated conditions. Phantom experiments showed measurable ihMT contrast and supported the feasibility of estimation using . In vivo experiments demonstrated simultaneous and MPF mapping using only three spin‐lock‐prepared images. Across 10 healthy volunteers, mean white matter values ranged from approximately 3.70 to 4.80 ms. By requiring only three contrast‐prepared images, the proposed technique provides a rapid framework for simultaneous and MPF mapping and may facilitate further investigation of dipolar‐order‐sensitive microstructural imaging in vivo.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingSpin LabelsHumansPhantoms, ImagingAlgorithmsBrain

Author keywords

dipolar orderinhomogeneous magnetization transferspin‐lock

Substances

Spin Labels

Authors and institutions

  • Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong.
  • MR Research Collaboration, Siemens Healthineers Ltd., Hong Kong.

ORCID profiles: Weitian Chen

Funding

  • Research Grants Council of the Hong Kong SAR

Cite

APA

Gao, Z., Shan, Q., Zhou, Z., Yu, Z., & Chen, W. (2026). Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70331

Vancouver

Gao Z, Shan Q, Zhou Z, Yu Z, Chen W. Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70331

BibTeX
@article{Gao2026,
  author = {Gao, Zijian and Shan, Qianxue and Zhou, Ziqin and Yu, Ziqiang and Chen, Weitian},
  title = {Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {7},
  doi = {10.1002/nbm.70331}
}
Start for free →