Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging
NMR in Biomedicine · 2026-07 · 39 (7)
DOI: 10.1002/nbm.70331 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 17.06.2026. Verfasst von Zijian Gao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Spin Labels. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Grants Council of the Hong Kong SAR.
Abstract (Originalsprache)
Inhomogeneous magnetization transfer (ihMT) is sensitive to dipolar order associated with motion‐restricted macromolecules and can be characterized by the dipolar relaxation time . In this study, we propose a spin‐lock MRI framework for quantification. Specifically, we introduce a ‐sensitive metric, , derived from the distinct relaxation rate , defined as the difference between dual‐frequency and single‐frequency measurements. To enable dual‐frequency spin‐lock acquisition, we developed a dedicated rotary‐echo spin‐lock sequence. Based on this framework, we further estimated and the macromolecular proton fraction (MPF) within a unified acquisition. The proposed method was evaluated using numerical simulations, phantom experiments, and in vivo imaging in the healthy human brain. Simulations demonstrated high sensitivity of to and supported the robustness of the proposed approach under the investigated conditions. Phantom experiments showed measurable ihMT contrast and supported the feasibility of estimation using . In vivo experiments demonstrated simultaneous and MPF mapping using only three spin‐lock‐prepared images. Across 10 healthy volunteers, mean white matter values ranged from approximately 3.70 to 4.80 ms. By requiring only three contrast‐prepared images, the proposed technique provides a rapid framework for simultaneous and MPF mapping and may facilitate further investigation of dipolar‐order‐sensitive microstructural imaging in vivo.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong.
- MR Research Collaboration, Siemens Healthineers Ltd., Hong Kong.
ORCID-Profile: Weitian Chen
Förderung
- Research Grants Council of the Hong Kong SAR
Zitieren
APA
Gao, Z., Shan, Q., Zhou, Z., Yu, Z., & Chen, W. (2026). Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70331
Vancouver
Gao Z, Shan Q, Zhou Z, Yu Z, Chen W. Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70331
BibTeX
@article{Gao2026,
author = {Gao, Zijian and Shan, Qianxue and Zhou, Ziqin and Yu, Ziqiang and Chen, Weitian},
title = {Dipolar Order Mapping Based on Spin‐Lock Magnetic Resonance Imaging},
journal = {NMR in Biomedicine},
year = {2026},
volume = {39},
number = {7},
doi = {10.1002/nbm.70331}
}
EUVIMED