EUVIMEDEUVIMED entdecken
Crossref

Cardiac Magnetic Resonance Fingerprinting for Simultaneous T1, T2, and Fat‐Fraction Quantification at 0.55 T

Diego Pedraza iD, Carlos Castillo-Passi iD, Karl Kunze, René M Botnar, Claudia Prieto

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70143 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Diego Pedraza und 4 weiteren Autor:innen. Beteiligte Einrichtung: Millennium Institute for Intelligent Healthcare Engineering, Chile. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Heart, Adipose Tissue. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: BHF program, King's BHF Centre for Award Excellence, Wellcome / EPSRC Centre for Medical Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac magnetic resonance fingerprinting (cMRF) has been shown to allow for simultaneous quantitative characterization of myocardial tissue in a single scan. While cMRF has been assessed at 1.5 T and 3 T, its application at 0.55 T has not been demonstrated yet. This study introduces an adapted version of a previously implemented Dixon cMRF sequence designed for simultaneous quantification of T1, T2, and fat fraction (FF) at 1.5 T, to be employed at 0.55 T within a single breath‐hold scan. The sequence was developed using the Pulseq environment and employs a radial tiny golden angle acquisition with bipolar readout. Reconstruction was performed using low‐rank inversion in combination with a high‐dimensional patch‐based regularization. The Dixon cMRF technique at 0.55 T was tested on standardized phantoms and 15 healthy volunteers (HVs). cMRF at 0.55 T was compared to spin‐echo (SE) and proton density references from phantoms, as well as conventional T1, T2, and FF mapping sequences at 0.55 T. Intrasession and intersession variability was assessed in phantoms and a representative HV. Results showed a good correlation between the proposed cMRF T1, T2, and FF at 0.55 T and the phantom IR‐SE references ( R 2 ≥ 0.98 for T1 and T2, R 2 ≥ 0.97 for FF). Intrasession variability was low (8.9 ± 13.8 ms for T1, 0.1 ± 1 ms for T2, and 0.02 ± 0.03% for FF), as was intersession variability (8.2 ± 8.5 ms, 0.4 ± 1.1 ms, and 0.02 ± 0.25%, respectively). In vivo assessments yielded good map quality, with mean myocardial values of 714 ± 24 ms for T1, 49 ± 5.9 ms for T2, and 2.6 ± 0.9% for FF in comparison to 672 ± 40 for T1‐MOLLI, 60 ± 5.4 for T2prep‐bSSFP, and 4.7 ± 2.4% for 2‐echo PDFF, respectively. The technique demonstrated good agreement for T1 and FF, but T2 was underestimated, which is consistent with findings at higher field strengths. Further investigation in a larger cohort of healthy subjects and in patients with cardiovascular disease is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHeartAdipose TissueHumansPhantoms, ImagingMaleFemaleAdultYoung Adult

Stichwörter der Autor:innen

T1 mappingT2 mappingcardiac MRIfat fractionlow fieldmagnetic resonance fingerprintingmultiparametric

Autor:innen und Institutionen

  • Millennium Institute for Intelligent Healthcare Engineering, Chile.
  • Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
  • Pontificia Universidad Católica de Chile, School of Engineering, Department of Electrical Engineering, Santiago, Chile.
  • MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
  • School of Biomedical Engineering, King's College London, London, UK.

ORCID-Profile: Diego Pedraza, Carlos Castillo-Passi

Förderung

  • BHF program
  • King's BHF Centre for Award Excellence
  • Wellcome / EPSRC Centre for Medical Engineering
  • Millennium Institute for Intelligent Healthcare Engineering
  • ANID
  • IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy
  • Centre For Medical Engineering, King’s College London

Zitieren

APA

Pedraza, D., Castillo-Passi, C., Kunze, K., Botnar, R. M., & Prieto, C. (2025). Cardiac Magnetic Resonance Fingerprinting for Simultaneous T1, T2, and Fat‐Fraction Quantification at 0.55 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.70143

Vancouver

Pedraza D, Castillo-Passi C, Kunze K, Botnar RM, Prieto C. Cardiac Magnetic Resonance Fingerprinting for Simultaneous T1, T2, and Fat‐Fraction Quantification at 0.55 T. NMR in Biomedicine. 2025. doi:10.1002/nbm.70143

BibTeX
@article{Pedraza2025,
  author = {Pedraza, Diego and Castillo-Passi, Carlos and Kunze, Karl and Botnar, René M and Prieto, Claudia},
  title = {Cardiac Magnetic Resonance Fingerprinting for Simultaneous T1, T2, and Fat‐Fraction Quantification at 0.55 T},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70143}
}
Kostenlos starten →