Repeatability of Myelin and Myelin Water Quantification Using Short‐TR Adiabatic Inversion‐Recovery Sequences
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70142 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von James Lo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of California, San Diego, California, USA. Hauptthemen laut MEDLINE: Myelin Sheath, Water, Magnetic Resonance Imaging, Body Water. Die Arbeit nennt 41 Literaturangaben. Gefördert von: GE Healthcare, NIH HHS, VA Clinical Science Research and Development Services Merit Award.
Abstract (Originalsprache)
Myelin and myelin water (MW) behavior is becoming increasingly relevant in their role in neurodegenerative diseases. Myelin proton fraction (MPF) and myelin water fraction (MWF) measured with short‐TR adiabatic inversion‐recovery (STAIR) sequences are potential biomarkers of myelin and MW, respectively, but their repeatabilities are unknown. This study aims to evaluate the repeatability of MPF and MWF measured with the STAIR ultrashort echo time (STAIR‐UTE) and STAIR short echo time (STAIR‐STE) sequences, respectively. 10 volunteers were scanned three times on different days using the same protocol, including 3D STAIR‐UTE for myelin mapping and STAIR‐STE for myelin water mapping on the same 3 T clinical scanner. The repeatability of each biomarker was analyzed by scan‐rescan correlation, Bland–Altman analyses, intraclass correlation coefficients (ICC), and coefficients of variation. There was no bias or significant difference between the three scans for MPF and MWF. Strong repeatability and intrareader/interreader agreement were demonstrated between repeated MPF and MWF measurements on each subject's scans. Strong repeatability was demonstrated for two myelin imaging biomarkers, MPF and MWF, highlighting the utility of STAIR sequences for reliable myelin mapping and potential applications in neuroinflammatory and neurodegenerative diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of California, San Diego, California, USA.
- Shu Chien-Gene Lay Department of Bioengineering, University of California, San Diego, California, USA.
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA.
ORCID-Profile: Soo Hyun Shin
Förderung
- GE Healthcare
- NIH HHS
- VA Clinical Science Research and Development Services Merit Award
- National Institutes of Health
Zitieren
APA
Lo, J., Wang, J., Tran, D., Chae, H. D., Nemeh, G., Athertya, J. S., Shin, S. H., Ma, Y., & Du, J. (2025). Repeatability of Myelin and Myelin Water Quantification Using Short‐TR Adiabatic Inversion‐Recovery Sequences. NMR in Biomedicine. https://doi.org/10.1002/nbm.70142
Vancouver
Lo J, Wang J, Tran D, Chae HD, Nemeh G, Athertya JS, et al. Repeatability of Myelin and Myelin Water Quantification Using Short‐TR Adiabatic Inversion‐Recovery Sequences. NMR in Biomedicine. 2025. doi:10.1002/nbm.70142
BibTeX
@article{Lo2025,
author = {Lo, James and Wang, Jiaji and Tran, Dylan and Chae, Hee Dong and Nemeh, Gabrielle and Athertya, Jiyo S and Shin, Soo Hyun and Ma, Yajun and Du, Jiang},
title = {Repeatability of Myelin and Myelin Water Quantification Using Short‐TR Adiabatic Inversion‐Recovery Sequences},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70142}
}
EUVIMED