EUVIMEDEUVIMED entdecken
Open Access

Variable Flip Angle Optimization for Fetal Brain Imaging With Reduced Specific Absorption Rate

Dominique Franson iD, Camilo Calixto, Hongli Fan, Camilo Jaimes, Clemente Velasco-Annis, Suely Fazio Ferraciolli, Cesar Alves, Edward Yang, Stephen Cauley, Ali Gholipour

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Dominique Franson und 9 weiteren Autor:innen. Beteiligte Einrichtung: Siemens Medical Solutions USA Inc, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Fetus. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, Office of the Director of the NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Half‐Fourier Acquisition with Single‐Shot Turbo Spin Echo (HASTE) scans are routinely used for fetal brain imaging, but they have a high specific absorption rate (SAR) and can be inefficient due to SAR limits. Here, we have designed an optimized variable flip angle (VFA) pattern for fetal HASTE neuroimaging to reduce both the SAR and repetition time (TR) of the HASTE sequence while maintaining similar image quality to standard fetal HASTE imaging with a constant flip angle (CFA). The VFA pattern was optimized by minimizing the difference in expected signal between the VFA and CFA scans while constraining the SAR of the VFA scan to no more than 65% of the SAR of the CFA scan and reducing the TR by 29%. The expected signal was calculated using an extended phase graph formalism, and simulations were used to predict the performance of the two scans using different image quality metrics. The proposed VFA and standard CFA scans were tested in phantoms and fetuses at 3 T. SAR and acquisition times were recorded, and image quality was rated by three radiologists. The VFA scan showed similar signal‐to‐noise ratio and contrast‐to‐noise ratio values but slightly lower signal and relative contrast values than the CFA scan in phantom studies. In vivo, the VFA scan yielded significantly reduced SAR, measurement times, and total scan times. There was no significant difference in overall image quality ratings between the VFA and CFA scans. An optimized VFA scan can provide 65% of the SAR and 71% of the acquisition time of a CFA scan while being diagnostically equivalent. Lower SAR reduces heating, eliminates SAR pauses, and allows accelerated scans by reducing the TR. The time saved by faster HASTE acquisitions increases patient comfort and may be used to repeat scans with excessive fetal motion or to perform advanced sequences.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainMagnetic Resonance ImagingFetusHumansPhantoms, ImagingFemalePregnancySignal-To-Noise Ratio

Stichwörter der Autor:innen

HASTEfetal MRIfetal brainsingle‐shot turbo spin echospecific absorption ratevariable flip angle

Autor:innen und Institutionen

  • Siemens Medical Solutions USA Inc, Boston, Massachusetts, USA.
  • Department of Radiology, Boston Children's Hospital, Boston, Massachusetts, USA.
  • Harvard Medical School, Boston, Massachusetts, USA.
  • Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Department of Radiological Sciences, and Department of Electrical Engineering and Computer Science, University of California Irvine, Irvine, California, USA.

ORCID-Profile: Dominique Franson

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • Office of the Director of the NIH
  • National Institute of Biomedical Imaging and Bioengineering
  • NIH Office of the Director

Zitieren

APA

Franson, D., Calixto, C., Fan, H., Jaimes, C., Velasco-Annis, C., Ferraciolli, S. F., Alves, C., Yang, E., Cauley, S., & Gholipour, A. (2025). Variable Flip Angle Optimization for Fetal Brain Imaging With Reduced Specific Absorption Rate. NMR in Biomedicine. https://doi.org/10.1002/nbm.70075

Vancouver

Franson D, Calixto C, Fan H, Jaimes C, Velasco-Annis C, Ferraciolli SF, et al. Variable Flip Angle Optimization for Fetal Brain Imaging With Reduced Specific Absorption Rate. NMR in Biomedicine. 2025. doi:10.1002/nbm.70075

BibTeX
@article{Franson2025,
  author = {Franson, Dominique and Calixto, Camilo and Fan, Hongli and Jaimes, Camilo and Velasco-Annis, Clemente and Ferraciolli, Suely Fazio and Alves, Cesar and Yang, Edward and Cauley, Stephen and Gholipour, Ali},
  title = {Variable Flip Angle Optimization for Fetal Brain Imaging With Reduced Specific Absorption Rate},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70075}
}
Kostenlos starten →