EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface

Vladislav Koloskov iD, Viktor Puchnin iD, Evgeniy Koreshin iD, Anna Kalugina, Wyger Brink iD, Polina Kozlova iD, Irina Mashchenko iD, Alena Shchelokova iD

NMR in Biomedicine · 2025-04 · 38 (4)

DOI: 10.1002/nbm.70016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 25.02.2025. Verfasst von Vladislav Koloskov und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Engineering, ITMO University, St. Petersburg, Russian Federation. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Fetus, Prenatal Diagnosis. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Russian Federation, Science and Universities, Russian Federation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recent advancements in magnetic resonance imaging (MRI) techniques are promising for the detection of fetal abnormalities, and MRI may supplement or replace prenatal ultrasound scans in the future. In particular, the interest of scientific and medical communities in high‐field (3T) MRI continues to grow due to its improved contrast‐to‐noise and signal‐to‐noise ratios compared to clinical MRI of lower field strength (1.5T). However, 3T MRI shows more prominent dielectric artifacts due to constructive and destructive interference of standing waves inside the body at these frequencies. Here, we present a concept of passive radiofrequency shimming using metasurface‐based pads to improve image quality in fetal MRI at 3T. The proposed metasurface increases the efficiency and homogeneity of the radiofrequency magnetic field, reducing dielectric artifacts in the fetal body and brain images. We offer an ultralight and compact passive way to improve 3T imaging of fetal brain and body structures, simplifying clinical workflows and decreasing the procedure time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingFetusPrenatal DiagnosisHumansFemalePregnancySignal-To-Noise RatioArtifactsBrain

Stichwörter der Autor:innen

dielectric artifactsfetal imagingfetus brainmagnetic resonance imagingmetasurfacespassive shimming

Autor:innen und Institutionen

  • School of Physics and Engineering, ITMO University, St. Petersburg, Russian Federation.
  • Magnetic Detection & Imaging Group, TechMed Centre, University of Twente, Enschede, the Netherlands.
  • Department of Radiology, Almazov National Medical Research Center, St. Petersburg, Russian Federation.

ORCID-Profile: Vladislav Koloskov, Viktor Puchnin, Evgeniy Koreshin, Wyger Brink, Polina Kozlova, Irina Mashchenko, Alena Shchelokova

Förderung

  • Ministry of Science and Higher Education of the Russian Federation
  • Science and Universities, Russian Federation

Zitieren

APA

Koloskov, V., Puchnin, V., Koreshin, E., Kalugina, A., Brink, W., Kozlova, P., Mashchenko, I., & Shchelokova, A. (2025). Improved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface. NMR in Biomedicine, 38(4). https://doi.org/10.1002/nbm.70016

Vancouver

Koloskov V, Puchnin V, Koreshin E, Kalugina A, Brink W, Kozlova P, et al. Improved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface. NMR in Biomedicine. 2025;38(4). doi:10.1002/nbm.70016

BibTeX
@article{Koloskov2025,
  author = {Koloskov, Vladislav and Puchnin, Viktor and Koreshin, Evgeniy and Kalugina, Anna and Brink, Wyger and Kozlova, Polina and Mashchenko, Irina and Shchelokova, Alena},
  title = {Improved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface},
  journal = {NMR in Biomedicine},
  year = {2025},
  volume = {38},
  number = {4},
  doi = {10.1002/nbm.70016}
}
Kostenlos starten →