Third trimester fetal 4D flow MRI with motion correction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Reagan M Tompkins und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Pregnancy Trimester, Third, Imaging, Three-Dimensional, Prenatal Diagnosis, Fetus. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, Colorado Fetal Care Centers, Pilot Funds, Society of Pediatric Radiology, Pilot Award.
Abstract (Originalsprache)
Purpose
To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods
A Doppler‐ultrasound fetal cardiac‐gated free‐running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed‐sensing reconstruction with a data outlier rejection algorithm was adapted from previous work. Pre‐ and post–motion correction comparison included qualitative visibility of vasculature on phase‐contrast MR angiograms (five‐point Likert scale), conservation of mass of the aortic isthmus, ductus arteriosus, and descending aorta, and coefficient of variation of flow along the descending aorta.
Results
Twenty‐nine third trimester acquisitions were performed for 15 healthy fetuses and two patients with postnatally confirmed aortic coarctation during a single examination for each participant. Only 15/27 (56%) of all volunteers and 1/2 (50%) of all patient precorrection acquisitions were suitable for flow analysis. Motion correction recovered eight “failed” acquisitions, including one patient, with 24/29 (83%) suitable for flow analysis. In the 15 viable uncorrected volunteer acquisitions, motion correction improved phase‐contrast MR angiograms visibility significantly in the ductus arteriosus (from 4.0 to 4.3, p = 0.04) and aortic arch (3.7 to 4.0, p = 0.03). Motion correction improved conservation of mass to a median (interquartile range) percent difference of 5% (9%) from 14% (24%) with improvement shown in 14/15 acquisitions ( p = 0.002), whereas coefficient of variation changes were not significantly different (uncorrected: 0.15 (0.09), corrected: 0.11 (0.09), p = 0.3).
Conclusions
Motion correction compensated for maternal and fetal motion in fetal 4D flow MRI data, improving image quality and conservation of mass.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
- Department of Radiology, Section of Pediatric Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
- Department of Pediatric Cardiology, Emma Children's Hospital, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
- Department of Pediatrics, Section of Cardiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
- Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
- Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
ORCID-Profile: Reagan M Tompkins, Takashi Fujiwara, Eric M Schrauben, Lorna P Browne, Joost van Schuppen, Sally-Ann Clur, Erin K Englund, Alex J Barker, Pim van Ooij
Förderung
- NCATS NIH HHS
- Colorado Fetal Care Centers, Pilot Funds
- Society of Pediatric Radiology, Pilot Award
- Stichting voor de Technische Wetenschappen
Zitieren
APA
Tompkins, R. M., Fujiwara, T., Schrauben, E. M., Browne, L. P., van Schuppen, J., Clur, S. A., Friesen, R. M., Englund, E. K., Barker, A. J., & van Ooij, P. (2025). Third trimester fetal 4D flow MRI with motion correction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30411
Vancouver
Tompkins RM, Fujiwara T, Schrauben EM, Browne LP, van Schuppen J, Clur SA, et al. Third trimester fetal 4D flow MRI with motion correction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30411
BibTeX
@article{Tompkins2025,
author = {Tompkins, Reagan M and Fujiwara, Takashi and Schrauben, Eric M and Browne, Lorna P and van Schuppen, Joost and Clur, Sally-Ann and Friesen, Richard M and Englund, Erin K and Barker, Alex J and van Ooij, Pim},
title = {Third trimester fetal 4D flow MRI with motion correction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30411}
}