EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A signal model for fat‐suppressed T 1 ‐mapping and dynamic contrast‐enhanced MRI with interrupted spoiled gradient‐echo readout

Myrte Wennen iD, Wilhelm Stehling, J Tim Marcus, Joost P A Kuijer iD, Cristina Lavini, Leo M A Heunks, Gustav J Strijkers iD, Bram F Coolen, Aart J Nederveen, Oliver J Gurney-Champion

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.5289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Myrte Wennen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Contrast Media, Phantoms, Imaging, Adipose Tissue. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: KWF-UVA, ZonMw.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The conventional gradient‐echo steady‐state signal model is the basis of various spoiled gradient‐echo (SPGR) based quantitative MRI models, including variable flip angle (VFA) MRI and dynamic contrast‐enhanced MRI (DCE). However, including preparation pulses, such as fat suppression or saturation bands, disrupts the steady‐state and leads to a bias in T 1 and DCE parameter estimates. This work introduces a signal model that improves the accuracy of VFA T 1 ‐mapping and DCE for interrupted spoiled gradient‐echo (I‐SPGR) acquisitions. The proposed model was applied to a VFA T 1 ‐mapping I‐SPGR sequence in the Gold Standard T 1 ‐phantom (3 T), in the brain of four healthy volunteers (3 T), and to an abdominal DCE examination (1.5 T). T 1 ‐values obtained with the proposed and conventional model were compared to reference T 1 ‐values. Bland–Altman analysis (phantom) and analysis of variance (in vivo) were used to test whether bias from both methods was significantly different ( p = 0.05). The proposed model outperformed the conventional model by decreasing the bias in the phantom with respect to the phantom reference values (mean bias ‐2 vs. ‐35% at 3 T) and in vivo with respect to the conventional SPGR (‐6 vs. ‐37% bias in T 1 , p < 0.01). The proposed signal model estimated approximately 48% (depending on baseline T 1 ) higher contrast concentrations in vivo, which resulted in decreased DCE pharmacokinetic parameter estimates of up to 35%. The proposed signal model improves the accuracy of quantitative parameter estimation from disrupted steady‐state I‐SPGR sequences. It therefore provides a flexible method for applying fat suppression, saturation bands, and other preparation pulses in VFA T 1 ‐mapping and DCE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingContrast MediaPhantoms, ImagingAdipose TissueHumansAdultMaleFemaleBrainSignal Processing, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

T1‐mappingdynamic contrast‐enhanced MRIfat suppressionspoiled gradient echovariable flip angle

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, The Netherlands.
  • Department of Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands.
  • Department of Intensive Care, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Department of Biomedical Engineering & Physics, Amsterdam University Medical Center, Amsterdam, The Netherlands.
  • Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands.

ORCID-Profile: Myrte Wennen, Joost P A Kuijer, Gustav J Strijkers

Förderung

  • KWF-UVA
  • ZonMw

Zitieren

APA

Wennen, M., Stehling, W., Marcus, J. T., Kuijer, J. P. A., Lavini, C., Heunks, L. M. A., Strijkers, G. J., Coolen, B. F., Nederveen, A. J., & Gurney-Champion, O. J. (2025). A signal model for fat‐suppressed T 1 ‐mapping and dynamic contrast‐enhanced MRI with interrupted spoiled gradient‐echo readout. NMR in Biomedicine. https://doi.org/10.1002/nbm.5289

Vancouver

Wennen M, Stehling W, Marcus JT, Kuijer JPA, Lavini C, Heunks LMA, et al. A signal model for fat‐suppressed T 1 ‐mapping and dynamic contrast‐enhanced MRI with interrupted spoiled gradient‐echo readout. NMR in Biomedicine. 2025. doi:10.1002/nbm.5289

BibTeX
@article{Wennen2025,
  author = {Wennen, Myrte and Stehling, Wilhelm and Marcus, J Tim and Kuijer, Joost P A and Lavini, Cristina and Heunks, Leo M A and Strijkers, Gustav J and Coolen, Bram F and Nederveen, Aart J and Gurney-Champion, Oliver J},
  title = {A signal model for fat‐suppressed T 1 ‐mapping and dynamic contrast‐enhanced MRI with interrupted spoiled gradient‐echo readout},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.5289}
}
Kostenlos starten →