Calculation of intravoxel incoherent motion parameter maps using a kernelized total difference‐based method
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5201 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Hsuan-Ming Huang. Beteiligte Einrichtung: Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, Taipei City, Taiwan. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Motion, Algorithms. Die Arbeit nennt 46 Literaturangaben. Gefördert von: National Science and Technology Council, Taiwan, National Science and Technology Council.
Abstract (Originalsprache)
Quantitative analysis of diffusion‐weighted magnetic resonance imaging (DW‐MRI) has been explored for many clinical applications since its development. In particular, the intravoxel incoherent motion (IVIM) model for DW‐MRI has been commonly utilized in various organs. However, because of the presence of excessive noise, the IVIM parameter maps obtained from pixel‐wise fitting are often unreliable. In this study, we propose a kernelized total difference‐based curve‐fitting method to estimate the IVIM parameters. Simulated DW‐MRI data at five signal‐to‐noise ratios (i.e., 10, 20, 30, 50, and 100) and real abdominal DW‐MRI data acquired on a 1.5‐T MRI scanner with nine b‐values (i.e., 0, 10, 25, 50, 100, 200, 300, 400, and 500 s/mm 2 ) and six diffusion‐encoding gradient directions were used to evaluate the performance of the proposed method. The results were compared with those obtained by three existing methods: trust‐region reflective (TRR) algorithm, Bayesian probability (BP), and deep neural network (DNN). Our simulation results showed that the proposed method outperformed the other three comparing methods in terms of root‐mean‐square error. Moreover, the proposed method could preserve small details in the estimated IVIM parameter maps. The experimental results showed that, compared with the TRR method, the proposed method as well as the BP (and DNN) method could reduce the overestimation of the pseudodiffusion coefficient and improve the quality of IVIM parameter maps. For all studied abdominal organs except the pancreas, both the proposed method and the BP method could provide IVIM parameter estimates close to the reference values; the former had higher precision. The kernelized total difference‐based curve‐fitting method has the potential to improve the reliability of IVIM parametric imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, Taipei City, Taiwan.
- Program for Precision Health and Intelligent Medicine, Graduate School of Advanced Technology, National Taiwan University, Taipei City, Taiwan.
ORCID-Profile: Hsuan-Ming Huang
Förderung
- National Science and Technology Council, Taiwan
- National Science and Technology Council
Zitieren
APA
Huang, H. M. (2024). Calculation of intravoxel incoherent motion parameter maps using a kernelized total difference‐based method. NMR in Biomedicine. https://doi.org/10.1002/nbm.5201
Vancouver
Huang HM. Calculation of intravoxel incoherent motion parameter maps using a kernelized total difference‐based method. NMR in Biomedicine. 2024. doi:10.1002/nbm.5201
BibTeX
@article{Huang2024,
author = {Huang, Hsuan-Ming},
title = {Calculation of intravoxel incoherent motion parameter maps using a kernelized total difference‐based method},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5201}
}
EUVIMED