A Comparative Study of IVIM ‐ MRI Fitting Techniques in Glioma Grading: Conventional, Bayesian, and Voxel‐Wise and Spatially‐Aware Deep Learning Approaches
Journal of Magnetic Resonance Imaging · 2026
DOI: 10.1002/jmri.70301 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Misha P T Kaandorp und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for MR Research, University Children's Hospital Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Glioma, Deep Learning, Diffusion Magnetic Resonance Imaging, Brain Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EMDO Foundation, Vontobel Foundation, Anna Müller-Grocholski.
Abstract (Originalsprache)
Background
Intravoxel incoherent motion (IVIM) analysis of diffusion‐weighted MRI (DWI) provides microvascular perfusion and diffusion information. However, parameter estimation is limited by noise sensitivity, variability across fitting methods, and lack of standardization. Deep‐learning (DL)–based approaches, particularly spatially‐aware transformers, may improve robustness, but their clinical utility remains unexplored.
Purpose
To evaluate conventional, Bayesian, and DL–based IVIM fitting methods in glioma patients, focusing on tumor grading accuracy. Study Type Retrospective. Population Fractal‐noise‐based simulations and preoperative DWI from 20 glioma patients (5 Grade‐2, 3 Grade‐3, 12 Grade‐4). Sequence Spin‐echo echo‐planar DWI, 16 b values (0–900 s/mm 2 ), three orthogonal directions, 3 T. Assessment IVIM parameter maps were compared across least squares (LSQ), segmented (SEG), Bayesian shrinkage (BSP), and spatial‐homogeneity (FBM) priors, and DL–based methods, including IVIM‐NET, novel spatially‐aware transformers (NATTEN‐17), and a refined version (SA‐17). Simulation accuracy was evaluated using median absolute percentage error (MDAPE) and bias using median percentage error. In vivo data were visually assessed by the authors for noise suppression and structural preservation. Whole‐tumor diffusion coefficient ( D ), pseudo‐diffusion coefficient ( D *), and signal fraction ( f ) values were evaluated across tumor grades and for differentiating Grade‐4 from Grade‐2/3 tumors. Statistical Tests Mann–Whitney U tests for group comparisons; tumor grading performance using receiver operating characteristic–area under the curve (ROC‐AUC), and pairwise AUC differences using the DeLong test. Significance: p < 0.05.
Results
Transformer‐based methods achieved superior simulation accuracy, with significantly lower MDAPE for f and D * than all other approaches: NATTEN‐17 (5.91%, 13.31%), SA‐17 (7.73%, 13.66%), LSQ (21.95%, 54.34%), SEG (17.10%, 21.27%), BSP (12.35%, 22.79%), FBM (16.32%, 20.67%). In vivo, they provided superior visual quality and tumor delineation in f and D * maps, producing seemingly denoised versions of LSQ, while preserving tumor heterogeneity. The spatially‐aware transformers yielded consistently the highest ROC‐AUC values, particularly for D * (SA‐17: 0.78), significantly outperforming LSQ (0.62), SEG (0.58), FBM (0.62), and IVIM‐NET (0.71). Data Conclusion Transformer‐based model fitting has the potential to provide clinically valuable IVIM parameter estimates and improved tumor grading accuracy. Evidence Level 3. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for MR Research, University Children's Hospital Zurich, Zurich, Switzerland.
- University of Zurich, Zurich, Switzerland.
- AI Medical AG, Zollikon, Switzerland.
- Kyoto Prefectural University of Medicine, Kyoto, Japan.
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.
- Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway.
ORCID-Profile: Misha P T Kaandorp, Andras Jakab, Christian Federau, Peter T While
Förderung
- EMDO Foundation
- Vontobel Foundation
- Anna Müller-Grocholski
- Prof. Max Cloetta Foundations
- Research Council of Norway
- Swiss National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- EMDO Stiftung
Zitieren
APA
Kaandorp, M. P. T., Jakab, A., Federau, C., & While, P. T. (2026). A Comparative Study of IVIM ‐ MRI Fitting Techniques in Glioma Grading: Conventional, Bayesian, and Voxel‐Wise and Spatially‐Aware Deep Learning Approaches. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70301
Vancouver
Kaandorp MPT, Jakab A, Federau C, While PT. A Comparative Study of IVIM ‐ MRI Fitting Techniques in Glioma Grading: Conventional, Bayesian, and Voxel‐Wise and Spatially‐Aware Deep Learning Approaches. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70301
BibTeX
@article{Kaandorp2026,
author = {Kaandorp, Misha P T and Jakab, Andras and Federau, Christian and While, Peter T},
title = {A Comparative Study of IVIM ‐ MRI Fitting Techniques in Glioma Grading: Conventional, Bayesian, and Voxel‐Wise and Spatially‐Aware Deep Learning Approaches},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
doi = {10.1002/jmri.70301}
}