Optimized analytical segmented method for improved intravoxel incoherent motion parameter extraction in low‐perfused tissues
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30636 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Erick O Buko und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, University of Minnesota, St. Paul, Minnesota, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Ischemia. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAMS NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
Intravoxel incoherent motion ( IVIM ) diffusion‐weighted imaging of tissue perfusion and diffusion has limited signal in low‐perfused tissues, which poses a challenge in measuring IVIM parameters. This work proposes an optimized analytical segmented ( opAS ) method for extracting IVIM parameters and compares its performance with prior segmented (S), oversegmented ( OS ), and analytical segmented ( AS ) fitting methods.
Methods
The four fitting methods were compared using numerical simulations and retrospective analysis of IVIM data of a piglet model of bone marrow ischemia. The simulations compared the accuracy and precision of the four methods for different combinations of IVIM perfusion‐related parameters ( D *, pseudo‐diffusion coefficient; and f, pseudo‐diffusion fraction) at a fixed molecular‐diffusion coefficient ( D ). In vivo data from n = 11 piglets were analyzed using the four methods to compare their sensitivities in detecting lack of perfusion in ischemic versus perfused pairs of femoral heads.
Results
In simulation, opAS had the lowest errors in estimating D , f , D *, and f × D * across all signal‐to‐noise ratio ( SNR) levels, particularly in challenging parameter combinations of low f and D *. In the piglet model, all four IVIM fitting methods consistently found that D increased and f and f × D * decreased in the ischemic versus perfused femoral heads. However, D * was only consistently decreased in the ischemic versus perfused femoral heads using the AS and opAS methods.
Conclusion
The opAS method more accurately estimates IVIM parameters than the S, OS , and AS approaches, particularly perfusion‐related parameters ( D * and f ) in low‐perfused tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Veterinary Clinical Sciences, University of Minnesota, St. Paul, Minnesota, USA.
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Erick O Buko, Casey P Johnson
Förderung
- NIAMS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Buko, E. O., Parvaze, S. P., & Johnson, C. P. (2025). Optimized analytical segmented method for improved intravoxel incoherent motion parameter extraction in low‐perfused tissues. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30636
Vancouver
Buko EO, Parvaze SP, Johnson CP. Optimized analytical segmented method for improved intravoxel incoherent motion parameter extraction in low‐perfused tissues. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30636
BibTeX
@article{Buko2025,
author = {Buko, Erick O and Parvaze, Suhail P and Johnson, Casey P},
title = {Optimized analytical segmented method for improved intravoxel incoherent motion parameter extraction in low‐perfused tissues},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30636}
}
EUVIMED