Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Haoqin Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Radio Waves. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of Hefei Anhui Province of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Inductively coupled radiofrequency (RF) coils are an inexpensive and simple method to realize wireless RF coils in magnetic resonance imaging (MRI), which can significantly ease the MRI scan setup and improve patient comfort because they do not require bulky components such as cables, baluns, preamplifiers, and connectors. However, volume‐type wireless coils are typically operated in transmit/receive mode because detuning such coils is much more challenging due to their complex structure and multiple resonant modes. Meanwhile, adding too many detuning circuits to a wireless coil would decrease the coil's quality factor, impair the signal‐to‐noise ratio, and increase the cost. In this work, we proposed, constructed, and tested a novel wireless volume coil based on the Litzcage design for 1.5‐T head imaging. Being an inductively coupled coil, it has a much simpler structure, resulting in a lighter weight and less bulky design. Despite its simpler structure, it exhibits comparable imaging performance with a commercial receive array, providing an alternative to conventional wired coils with a high cost and complex structure. The unique figure‐of‐8 conductor pattern within the rungs ensures that the proposed wireless Litzcage can be efficiently detuned with minimal detuning circuits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRadio WavesHumansSignal-To-Noise RatioEquipment DesignPhantoms, Imaging

Stichwörter der Autor:innen

LitzcageRF coilbirdcagedetunewireless coil

Autor:innen und Institutionen

  • Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada.
  • Department of Physics, The University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA.
  • Hubei Key Laboratory of Intelligent Conveying Technology and Device, Hubei Polytechnic University, Huangshi, China.
  • The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, China.
  • Sino Canada Health Engineering Research Institute (Hefei) Ltd., Hefei, Anhui, China.

Förderung

  • Natural Science Foundation of Hefei Anhui Province of China

Zitieren

APA

Zhu, H., Lang, M. L., Yang, Y., Martin, M., Zhang, G., Zhang, Q., Chen, Y., & Yan, X. (2024). Detunable wireless Litzcage coil for human head MRI at 1.5 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.5068

Vancouver

Zhu H, Lang ML, Yang Y, Martin M, Zhang G, Zhang Q, et al. Detunable wireless Litzcage coil for human head MRI at 1.5 T. NMR in Biomedicine. 2024. doi:10.1002/nbm.5068

BibTeX
@article{Zhu2024,
  author = {Zhu, Haoqin and Lang, Michael L and Yang, Yijin and Martin, Melanie and Zhang, Gong and Zhang, Qiang and Chen, Yuanyuan and Yan, Xinqiang},
  title = {Detunable wireless Litzcage coil for human head MRI at 1.5 T},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5068}
}
Kostenlos starten →