EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Double‐row 16‐element folded‐end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T

Anton V Nikulin, Dario Bosch, Georgiy A Solomakha, Felix Glang iD, Klaus Scheffler, Nikolai I Avdievich iD

NMR in Biomedicine · 2023-10 · 36 (10)

DOI: 10.1002/nbm.4981 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 10.06.2023. Verfasst von Anton V Nikulin und 5 weiteren Autor:innen. Beteiligte Einrichtung: High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Russian Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Homogeneity and longitudinal coverage of transmit (Tx) human head RF coils at ultrahigh field (UHF, ≥7 T) can be improved by 3D RF shimming, which requires using multi‐row Tx arrays. Examples of 3D RF shimming using double‐row UHF loop transceiver (TxRx) and Tx arrays have been described previously. Dipole antennas provide unique simplicity and robustness while offering comparable Tx efficiency and signal‐to‐noise ratio to conventional loop designs. Single‐row Tx and TxRx human head UHF dipole arrays have been previously described by multiple groups. Recently, we developed a novel type of dipole antenna, a folded‐end dipole, and presented single‐row eight‐element array prototypes for human head imaging at 7 and 9.4 T. These studies have shown that the novel antenna design can improve the longitudinal coverage and minimize peak local specific absorption rate (SAR) as compared with common unfolded dipoles. In this work, we developed, constructed, and evaluated a 16‐element double‐row TxRx folded‐end dipole array for human head imaging at 9.4 T. To minimize cross‐talk between neighboring dipoles located in different rows, we used transformer decoupling, which decreased coupling to a level below −20 dB. The developed array design was demonstrated to be capable of 3D static RF shimming and can be potentially used for dynamic shimming using parallel transmission. For optimal phase shifts between the rows, the array provides 11% higher SAR efficiency and 18% higher homogeneity than a folded‐end dipole single‐row array of the same length. The design also offers a substantially simpler and more robust alternative to the common double‐row loop array with about 10% higher SAR efficiency and better longitudinal coverage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainHumansPhantoms, ImagingSignal-To-Noise RatioEquipment Design

Stichwörter der Autor:innen

3D RF shimmingarray optimizationdecouplingfolded-end dipolehuman head imagingtransceiver arrayultrahigh field MRI

Autor:innen und Institutionen

  • High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany.
  • Center of Photonics and 2D Materials, Moscow Institute of Physics and Technology, Dolgoprudny, Russia.
  • Department of Physics and Engineering, ITMO University, St. Petersburg, Russia.

ORCID-Profile: Felix Glang, Nikolai I Avdievich

Förderung

  • Russian Science Foundation

Zitieren

APA

Nikulin, A. V., Bosch, D., Solomakha, G. A., Glang, F., Scheffler, K., & Avdievich, N. I. (2023). Double‐row 16‐element folded‐end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T. NMR in Biomedicine, 36(10). https://doi.org/10.1002/nbm.4981

Vancouver

Nikulin AV, Bosch D, Solomakha GA, Glang F, Scheffler K, Avdievich NI. Double‐row 16‐element folded‐end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T. NMR in Biomedicine. 2023;36(10). doi:10.1002/nbm.4981

BibTeX
@article{Nikulin2023,
  author = {Nikulin, Anton V and Bosch, Dario and Solomakha, Georgiy A and Glang, Felix and Scheffler, Klaus and Avdievich, Nikolai I},
  title = {Double‐row 16‐element folded‐end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T},
  journal = {NMR in Biomedicine},
  year = {2023},
  volume = {36},
  number = {10},
  doi = {10.1002/nbm.4981}
}
Kostenlos starten →