EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Dual‐frequency resonant coil design for low‐γ X‐nuclear and proton magnetic resonance imaging at ultrahigh fields

Guangle Zhang, Wei Zhu, Xin Li iD, Soo Han Soon, Xiao-Hong Zhu, Wei Chen iD

NMR in Biomedicine · 2023

DOI: 10.1002/nbm.4930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2023. Verfasst von Guangle Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research (CMRR), Department of Radiology, University of Minnesota, Minnesota, USA. Hauptthemen laut MEDLINE: Protons, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, NIMH NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low‐γ X‐nuclear MRS and imaging have played a key role in studying metabolism and physiopathology, especially at ultrahigh fields. We design and demonstrate a novel and simple dual‐frequency RF resonant coil that can operate at both low‐γ X‐nuclear and proton frequencies. The dual‐frequency resonant coil comprises an LC coil loop and a tuning‐matching circuit bridged by two short wires of the desired length to generate two resonant modes: one for proton MRI and the other for low‐γ X‐nuclear MRS imaging with a large difference in their Larmor frequencies at ultrahigh fields. The coil parameters for the desired coil size and resonant frequencies can be determined via numerical simulations based on LC circuit theory. We designed, constructed, and evaluated several prototype surface coils and quadrature array coils for 1 H and 2 H or 17 O imaging, with small‐sized (diameter ≤ 5 cm) coils evaluated using a 16.4 T animal scanner, and a large‐sized (15 cm diameter) coil on a 7 T human scanner. All coils could be tuned/matched and driven in the single coil or array coil mode to the resonant frequencies of 1 H (698 and 298 MHz), 2 H (107 and 45.8 MHz), or 17 O (94.7 and 40.4 MHz) for imaging measurements and evaluation at 16.4 and 7 T, respectively. The dual‐frequency resonant coil or array provides adequate detection sensitivity for 1 H MRI and excellent performance for low‐γ X‐nuclear MRS imaging applications, and excellent coil decoupling efficiency between the array coils at both resonant frequencies with an optimal geometric overlap. It provides a simple, cost‐effective dual‐frequency RF coil solution to perform low‐γ X‐nuclear MRS imaging for preclinical and human applications, especially at ultrahigh fields.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProtonsMagnetic Resonance ImagingAnimalsHumansPhantoms, ImagingEquipment DesignTransducers

Stichwörter der Autor:innen

chemical shift imaging, dual-frequency resonant coil designlow-γ X-nuclear MRS imagingproton MRIultrahigh fields

Substanzen

Protons

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research (CMRR), Department of Radiology, University of Minnesota, Minnesota, USA.

ORCID-Profile: Xin Li, Wei Chen

Förderung

  • NIBIB NIH HHS
  • NIMH NIH HHS
  • NINDS NIH HHS
  • NCRR NIH HHS
  • NCI NIH HHS
  • National Center for Advancing Translational Sciences

Zitieren

APA

Zhang, G., Zhu, W., Li, X., Soon, S. H., Zhu, X. H., & Chen, W. (2023). Dual‐frequency resonant coil design for low‐γ X‐nuclear and proton magnetic resonance imaging at ultrahigh fields. NMR in Biomedicine. https://doi.org/10.1002/nbm.4930

Vancouver

Zhang G, Zhu W, Li X, Soon SH, Zhu XH, Chen W. Dual‐frequency resonant coil design for low‐γ X‐nuclear and proton magnetic resonance imaging at ultrahigh fields. NMR in Biomedicine. 2023. doi:10.1002/nbm.4930

BibTeX
@article{Zhang2023,
  author = {Zhang, Guangle and Zhu, Wei and Li, Xin and Soon, Soo Han and Zhu, Xiao-Hong and Chen, Wei},
  title = {Dual‐frequency resonant coil design for low‐γ X‐nuclear and proton magnetic resonance imaging at ultrahigh fields},
  journal = {NMR in Biomedicine},
  year = {2023},
  doi = {10.1002/nbm.4930}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche