Single breath‐hold three‐dimensional whole‐heart T 2 mapping with low‐rank plus sparse reconstruction
NMR in Biomedicine · 2023
DOI: 10.1002/nbm.4924 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2023. Verfasst von Dongyue Si und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Heart. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
The purpose of the current study was to develop and evaluate a three‐dimensional single Breath‐hOLd cardiac T 2 mapping sequence (3D BOLT) with low‐rank plus sparse (L + S) reconstruction for rapid whole‐heart T 2 measurement. 3D BOLT collects three highly accelerated electrocardiogram‐triggered volumes with whole‐heart coverage, all within a single 12‐heartbeat breath‐hold. Saturation pulses are performed every heartbeat to prepare longitudinal magnetization before T 2 preparation (T 2 ‐prep) or readout, and the echo time of T 2 ‐prep is varied per volume for variable T 2 weighting. Accelerated volumes are reconstructed jointly by an L + S algorithm. 3D BOLT was optimized and validated against gradient spin echo (GraSE) and a previously published approach (three‐dimensional free‐breathing cardiac T 2 mapping [3DFBT2]) in both phantoms and human subjects (11 healthy subjects and 10 patients). The repeatability of 3D BOLT was validated on healthy subjects. Retrospective experiments indicated that 3D BOLT with 4.2‐fold acceleration achieved T 2 measurements comparable with those obtained with fully sampled data. T 2 measured in phantoms using 3D BOLT demonstrated good accuracy and precision compared with the reference (R 2 > 0.99). All in vivo imaging was successful and the average left ventricle T 2 s measured by GraSE, 3DFBT2, and 3D BOLT were comparable and consistent for all healthy subjects (47.0 ± 2.3 vs. 47.7 ± 2.7 vs. 48.4 ± 1.8 ms) and patients (50.8 ± 3.0 vs. 48.6 ± 3.9 vs. 49.1 ± 3.7 ms), respectively. Myocardial T 2 measured by 3D BOLT had excellent agreement with 3DFBT2 and there was no significant difference in mean, standard deviation, and coefficient of variation. 3D BOLT showed excellent repeatability (intraclass correlation coefficient: 0.938). The proposed 3D BOLT achieved whole‐heart T 2 mapping in a single breath‐hold with good accuracy, precision, and repeatability on T 2 measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China.
- School of medical technology, Beijing Institute of Technology, Beijing, China.
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.
ORCID-Profile: Dongyue Si, Haiyan Ding
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Si, D., Kong, X., Guo, R., Cheng, L., Ning, Z., Chen, Z., Chen, S., Herzka, D. A., & Ding, H. (2023). Single breath‐hold three‐dimensional whole‐heart T 2 mapping with low‐rank plus sparse reconstruction. NMR in Biomedicine. https://doi.org/10.1002/nbm.4924
Vancouver
Si D, Kong X, Guo R, Cheng L, Ning Z, Chen Z, et al. Single breath‐hold three‐dimensional whole‐heart T 2 mapping with low‐rank plus sparse reconstruction. NMR in Biomedicine. 2023. doi:10.1002/nbm.4924
BibTeX
@article{Si2023,
author = {Si, Dongyue and Kong, Xiangchuang and Guo, Rui and Cheng, Lan and Ning, Zihan and Chen, Zhensen and Chen, Shuo and Herzka, Daniel A and Ding, Haiyan},
title = {Single breath‐hold three‐dimensional whole‐heart T 2 mapping with low‐rank plus sparse reconstruction},
journal = {NMR in Biomedicine},
year = {2023},
doi = {10.1002/nbm.4924}
}
EUVIMED