EUVIMEDEUVIMED entdecken
Vergleichsstudie

Free-breathing 3D pancreatic water T1 mapping using radial sampling technique: comparison with conventional 2D technique

Shingo Omata, Yoshifumi Noda, Akio Ito, Nobuyuki Kawai, Tetsuro Kaga, Yusuke Ohashi, Satoshi Ido, Kimihiro Kajita, Yu Ueda, Abdelazim Elsayed Elhelaly, Hirohiko Imai, Hiroki Kato und 1 weitere

Magnetic Resonance Imaging · 2026

DOI: 10.1016/j.mri.2026.110764 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Shingo Omata und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Pancreas, Magnetic Resonance Imaging. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to compare the clinical feasibility and measurement performance of free-breathing three-dimensional (3D) pancreatic water T1 mapping between a 3D radial 6-point DIXON Look-Locker (3D-LL) technique and a conventional breath-hold two-dimensional Look-Locker (2D-LL) technique. METHODS: Six phantom syringes, comprising three organ-equivalent phantoms and three serial gadolinium dilution phantoms, were scanned using inversion recovery (IR), 2D-LL, and 3D-LL techniques. Pearson correlation coefficient and Bland-Altman analyses were used to assess measurement accuracy relative to IR and agreement between 2D-LL and 3D-LL, respectively. This prospective clinical study included 45 participants who underwent breath-hold 2D-LL T1 mapping and free-breathing 3D-LL pancreatic water T1 mapping. Two independent readers measured T1 values in the pancreatic head, body, and tail, and calculated whole-pancreas averages. Nonevaluable regions were recorded. T1 values were compared between the two techniques using the Wilcoxon signed-rank test. RESULTS: Phantom experiments demonstrated very strong correlations with IR for both techniques (2D-LL, r = 0.9998; 3D-LL, r = 0.9993), and Bland-Altman analysis revealed a small positive bias of 3D-LL over 2D-LL (+15.1 ms). A clinical study revealed coverage- or motion-related regional failures that precluded T1 measurement in six participants (13%) with 2D-LL, but in none with 3D-LL. The median T1 values in the pancreatic head (P = 0.25), body (P = 0.21), tail (P = 0.25), and whole-pancreas average (P = 0.17) did not differ significantly between the two techniques. CONCLUSION: The 3D-LL technique demonstrated accurate T1 quantification in phantoms, comparable to IR and 2D-LL. Clinical data indicated that the 3D-LL technique improves pancreatic measurability by avoiding coverage- and motion-related regions that are not amenable to T1 measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalPancreasMagnetic Resonance ImagingHumansPhantoms, ImagingFemaleMaleAdultProspective StudiesMiddle AgedRespirationReproducibility of ResultsAgedBreath HoldingWaterFeasibility StudiesGadoliniumImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Free-breathing 3D acquisitionLook-Locker sequenceMagnetic resonance imagingPancreasWater T1mapping

Substanzen

WaterGadolinium

Autor:innen und Institutionen

  • Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.
  • Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan; Department of Frontier Science for Imaging, Gifu University, Gifu, Japan. Electronic address: noda.yoshifumi.g9@f.gifu-u.ac.jp.
  • Department of Radiology Services, Gifu University Hospital, Gifu, Japan.
  • Philips Japan, Konan 2-13-37, Minato-ku, Tokyo 108-8507, Japan.
  • Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan; Department of Frontier Science for Imaging, Gifu University, Gifu, Japan; Department of Food Hygiene and Control, Faculty of Veterinary Medic…
  • Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan; Innovation Research Center for Quantum Medicine, Graduate School of Medicine, Gifu University, Gifu, Japan.

Zitieren

APA

Omata, S., Noda, Y., Ito, A., Kawai, N., Kaga, T., Ohashi, Y., Ido, S., Kajita, K., Ueda, Y., Elhelaly, A. E., Imai, H., Kato, H., & Matsuo, M. (2026). Free-breathing 3D pancreatic water T1 mapping using radial sampling technique: comparison with conventional 2D technique. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110764

Vancouver

Omata S, Noda Y, Ito A, Kawai N, Kaga T, Ohashi Y, et al. Free-breathing 3D pancreatic water T1 mapping using radial sampling technique: comparison with conventional 2D technique. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110764

BibTeX
@article{Omata2026,
  author = {Omata, Shingo and Noda, Yoshifumi and Ito, Akio and Kawai, Nobuyuki and Kaga, Tetsuro and Ohashi, Yusuke and Ido, Satoshi and Kajita, Kimihiro and Ueda, Yu and Elhelaly, Abdelazim Elsayed and Imai, Hirohiko and Kato, Hiroki and Matsuo, Masayuki},
  title = {Free-breathing 3D pancreatic water T1 mapping using radial sampling technique: comparison with conventional 2D technique},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2026.110764}
}
Kostenlos starten →