EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Reference‐Superimposed Reconstruction ( RS ‐Recon) for Arterial Spin Labeling

Jia Guo iD

Magnetic Resonance in Medicine · 2026-12 · 96 (6) · 2685-2697

DOI: 10.1002/mrm.70540 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-07-26. Written by Jia Guo. Institution: Department of Bioengineering, University of California Riverside, Riverside, California, USA. Major MEDLINE topics: Image Processing, Computer-Assisted, Brain, Magnetic Resonance Imaging. Cited 1 times so far (Crossref); 17 references. The full text is freely available (open access, CC BY 4.0). Funded by: NCI NIH HHS, NIBIB NIH HHS, NIH HHS.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

Conventional arterial spin labeling (ASL) reconstruction suffers from sign‐flipping errors and/or noise bias under strong background suppression (BS), limiting SNR optimization. We propose reference‐superimposed reconstruction (RS‐recon) to enable ideal BS and robust signal recovery.

Methods

RS‐recon superimposes high‐SNR M 0 k ‐space data onto ASL k ‐space before reconstruction, with subsequent reference subtraction. Four volunteers underwent 3T scanning with pulsed ASL, pseudo‐continuous ASL, and dual‐module velocity‐selective ASL across varying BS levels. RS‐recon integrated reconstruction pipelines were compared to standard magnitude (Mag), complex subtraction (ComplexSub), and complex (Complex) reconstruction pipelines. The performance was evaluated by metrics including ASL signal, temporal SNR (tSNR), artifacts, misalignment robustness, and generalized auto‐calibrating partially parallel acquisitions (GRAPPA) compatibility.

Results

RS‐recon eliminated subtraction artifacts due to signal sign‐flipping, recovered negative ASL signals, and enabled ideal BS for maximizing SNR. It significantly improved ASL signal and tSNR in gray/white matter across all labeling methods and different BS conditions. RS‐recon corrected phase errors under low‐SNR conditions, preserved signal signs, maintained Gaussian noise distribution, remained robust against misalignments between the reference and the ASL images, and integrated well with GRAPPA. Mag + RS performance matched complex‐based (ComplexSub and Complex) RS pipelines and is recommended for its simplicity, compatibility, and robustness overall.

Conclusion

RS‐recon offers a simple, robust strategy for ASL image reconstruction, resolving subtraction errors even with magnitude output and enabling optimal background suppression. It enhances signal fidelity, SNR, and phase accuracy while integrating seamlessly with existing reconstruction pipelines and parallel imaging.

Subjects

MeSH terms (MEDLINE)

Image Processing, Computer-AssistedBrainMagnetic Resonance ImagingHumansSpin LabelsArtifactsSignal-To-Noise RatioAlgorithmsMaleAdultPerfusion Magnetic Resonance ImagingCerebrovascular CirculationFemale

Author keywords

arterial spin labelingbackground suppressionimage reconstructionlow‐SNR signal recoveryphase estimation

Substances

Spin Labels

Authors and institutions

  • Department of Bioengineering, University of California Riverside, Riverside, California, USA.

ORCID profiles: Jia Guo

Funding

  • NCI NIH HHS
  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Guo, J. (2026). Reference‐Superimposed Reconstruction ( RS ‐Recon) for Arterial Spin Labeling. Magnetic Resonance in Medicine, 96(6), 2685-2697. https://doi.org/10.1002/mrm.70540

Vancouver

Guo J. Reference‐Superimposed Reconstruction ( RS ‐Recon) for Arterial Spin Labeling. Magnetic Resonance in Medicine. 2026;96(6):2685-2697. doi:10.1002/mrm.70540

BibTeX
@article{Guo2026,
  author = {Guo, Jia},
  title = {Reference‐Superimposed Reconstruction ( RS ‐Recon) for Arterial Spin Labeling},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {6},
  pages = {2685--2697},
  doi = {10.1002/mrm.70540}
}
Start for free →