EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord

Alicia E Cronin iD, Alexandre D'Astous iD, Nathan Williams, Antoine Guénette, Aimee Salakhov, Seth Stubblefield iD, Colin D McKnight, Lipika Narisetti, Subramaniam Sriram, Seth A Smith, Ryan K Robison, Guillaume Gilbert and 2 more

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70528 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Alicia E Cronin and 13 co-authors. Institution: Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Major MEDLINE topics: Spinal Cord, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Multiple Sclerosis. 32 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, Canada Research Chair in Quantitative Magnetic Resonance Imaging, Natural Sciences and Engineering Research Council of Canada.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

In the spinal cord (SC), multi‐echo gradient echo (ME‐GRE) increases gray (GM) and white matter (WM) contrast and improves sensitivity to lesions in people with multiple sclerosis (pwMS). However, SC ME‐GRE is susceptible to breathing‐induced field fluctuations, causing ghosting artifacts and signal loss. Recent work introduced a 1D phase navigator following the last echo to measure field variations; however, susceptibility to phase wrapping increases at longer echo times. We propose a 1D phase navigator preceding the first echo, reducing phase accumulation and eliminating the need for respiratory monitoring.

Methods

ME‐GRE data covering the lower (T9–T12 vertebrae) and upper (T4–T8 vertebrae) thoracic SC were acquired in 20 healthy volunteers and 3 pwMS at 3T. Standard and navigator‐corrected images were acquired in the same acquisition. To evaluate image quality, WM and GM signal‐to‐noise ratio (SNR), WM/GM contrast‐to‐noise ratio (CNR), and background ghosting signals were measured and compared between the two reconstructions. Both were blindly assessed for artifacts, structural delineation, and diagnostic confidence in pwMS.

Results

Navigator correction significantly increased GM and WM SNR and CNR, reduced posterior ghosting across both thoracic regions, and significantly reduced artifacts while increasing structural delineation. Preliminary evaluation in three pwMS showed consistent improvements in artifact mitigation, structural delineation, and lesion conspicuity with navigator correction, providing proof‐of‐concept for potential clinical application.

Conclusion

A 1D navigator prior to the first echo reduces ghosting and improves thoracic SC image quality without respiratory monitoring. This approach could improve the diagnostic value and enhance the reliability of thoracic SC ME‐GRE.

Subjects

MeSH terms (MEDLINE)

Spinal CordImage Processing, Computer-AssistedMagnetic Resonance ImagingMultiple SclerosisEcho-Planar ImagingHumansArtifactsAdultFemaleMaleSignal-To-Noise RatioThoracic VertebraeRespirationAlgorithmsGray MatterWhite MatterReproducibility of ResultsHealthy VolunteersMiddle Aged

Author keywords

B0 field fluctuationsartifactsmulti‐echo gradient‐echonavigator correctionspinal cord

Authors and institutions

  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique, Montréal, Quebec, Canada.
  • Centre de Recherche du CHU Sainte-Justine, Université de Montréal, Montréal, Quebec, Canada.
  • Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
  • Neuroimmunology Division, Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

ORCID profiles: Alicia E Cronin, Alexandre D'Astous, Seth Stubblefield, Kristin P O'Grady

Funding

  • NIH HHS
  • Canada Research Chair in Quantitative Magnetic Resonance Imaging
  • Natural Sciences and Engineering Research Council of Canada
  • National Multiple Sclerosis Society
  • Santé
  • Canada First Research Excellence Fund
  • CIHR
  • Canada Foundation for Innovation

Cite

APA

Cronin, A. E., D'Astous, A., Williams, N., Guénette, A., Salakhov, A., Stubblefield, S., McKnight, C. D., Narisetti, L., Sriram, S., Smith, S. A., Robison, R. K., Gilbert, G., Cohen-Adad, J., & O'Grady, K. P. (2026). 1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70528

Vancouver

Cronin AE, D'Astous A, Williams N, Guénette A, Salakhov A, Stubblefield S, et al. 1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70528

BibTeX
@article{Cronin2026,
  author = {Cronin, Alicia E and D'Astous, Alexandre and Williams, Nathan and Guénette, Antoine and Salakhov, Aimee and Stubblefield, Seth and McKnight, Colin D and Narisetti, Lipika and Sriram, Subramaniam and Smith, Seth A and Robison, Ryan K and Gilbert, Guillaume and Cohen-Adad, Julien and O'Grady, Kristin P},
  title = {1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70528}
}
Start for free →