EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp–Logan

Tamás Hakkel iD, Noémi Kovács, József Sinkó, Domokos Máthé iD, Krisztián Szigeti iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70495 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Tamás Hakkel and 4 co-authors. Institution: Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary. Major MEDLINE topics: Phantoms, Imaging, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Image Interpretation, Computer-Assisted. 17 references. The full text is freely available (open access, CC BY 4.0). Funded by: Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, Mesterséges Intelligencia Nemzeti Laboratórium, European Union's Horizon 2020 Research and Innovation Program.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

A customizable, dynamic geometric phantom was developed to bridge the gap between simplistic static phantoms and highly realistic, complex 4D solutions. The phantom enables initial testing, helps detect implementation errors, and supports quantitative evaluation of new dynamic acquisition and reconstruction methods. It is formed from a series of superellipsoids using the constructive solid geometry technique and serves as a schematic representation of a human torso, including the lungs, liver, and stomach, as well as a four‐chamber heart, major vessels, and simplified skeletal structures. This design allows full parameterization of voxel intensities and organ volumes. Respiratory and cardiac motions are modeled using built‐in, decoupled signal generators. A high‐performance, open‐source reference implementation was developed in Julia and is available both as a library and a standalone console application. The phantom's capabilities were demonstrated through four experiments. The difference between the input and measured lung volumes was quantified, yielding a maximum relative error of 5.5% and a median error of 2.5%. The relative error of the cardiac chamber volumes ranged from 1.76% to 3.67%. Performance was benchmarked across multiple phantom sizes and thread counts, and a realistic Cartesian MRI simulation demonstrated how the phantom can be used to quantify motion blur and artifacts. The proposed dynamic geometric phantom provides an intermediate option between simple static phantoms and complex, proprietary, anatomically realistic 4D models. It provides a highly customizable, easy‐to‐use, open‐source tool for researchers developing new reconstruction algorithms, and it can be easily integrated into existing reconstruction pipelines.

Subjects

MeSH terms (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingTomography, X-Ray ComputedImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedHumansReproducibility of ResultsAlgorithmsSensitivity and SpecificityEquipment Design

Author keywords

CTJuliaMRIShepp–Loganconstructive solid geometrydynamic phantom

Authors and institutions

  • Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary.
  • Mediso Medical Imaging Systems Ltd, Budapest, Hungary.
  • Hungarian Centre of Excellence for Molecular Medicine (HCEMM), Szeged, Hungary.

ORCID profiles: Tamás Hakkel, Domokos Máthé, Krisztián Szigeti

Funding

  • Nemzeti Kutatási Fejlesztési és Innovációs Hivatal
  • Mesterséges Intelligencia Nemzeti Laboratórium
  • European Union's Horizon 2020 Research and Innovation Program
  • Horizon 2020 Framework Programme

Cite

APA

Hakkel, T., Kovács, N., Sinkó, J., Máthé, D., & Szigeti, K. (2026). A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp–Logan. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70495

Vancouver

Hakkel T, Kovács N, Sinkó J, Máthé D, Szigeti K. A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp–Logan. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70495

BibTeX
@article{Hakkel2026,
  author = {Hakkel, Tamás and Kovács, Noémi and Sinkó, József and Máthé, Domokos and Szigeti, Krisztián},
  title = {A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp–Logan},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70495}
}
Start for free →