4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70493 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Alessandra Riva und 13 weiteren Autor:innen. Beteiligte Einrichtung: 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, San Donato Milanese, Italy. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Image Interpretation, Computer-Assisted, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Italian Ministry of Health (Ricerca Corrente), Ministero della Salute.
Abstract (Originalsprache)
Purpose
To address limitations in tricuspid regurgitation (TR) quantification by magnetic resonance imaging (MRI) or transthoracic echocardiography (TTE), a new method is proposed to directly quantify TR volume (TR V ) using 4D Flow MRI with retrospective tricuspid valve (TV) annular tracking.
Methods
Thirty patients with TR were prospectively enrolled. TR V was quantified using four MRI‐based methods: (i) indirect, (ii) direct (2D phase‐contrast), (iii) 4D Flow with a static TV plane, and (iv) 4D Flow with dynamic annular tracking. Reproducibility and agreement were assessed in terms of TR grading against standard MRI‐ and TTE‐based methods.
Results
The dynamic 4D Flow method correlated strongly with all other MRI methods ( r = 0.77–0.81, p < 0.0001) but consistently yielded higher TR V values. Compared with the indirect method, it showed a Bland–Altman bias of 16 mL (limits of agreement: −19 to 51 mL), along with the highest agreement (intraclass correlation coefficient of 0.88). Agreement in TR severity grading was poor across methods (kappa ≤ 0.07), with dynamic 4D Flow classifying more cases as moderate or severe. Agreement with TTE was slight (kappa = 0.17, p = 0.27) with concordant TR grading in 50% of patients. Inter‐observer reproducibility was excellent ( r = 0.99, bias = 0.7 mL, kappa = 0.80).
Conclusion
4D Flow with dynamic TV tracking offers a reproducible and potentially more sensitive method for TR V quantification than conventional MRI techniques. Despite limited alignment with TTE, this technique may help overcome key imaging limitations and improve TR clinical evaluation, especially in complex cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, San Donato Milanese, Italy.
- Pediatric and Adult Congenital Disease Heart Centre, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
- Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
- Department of Radiology, IRCCS Foundation Ca' Granda Ospedale Maggiore Policlinico, University of Milan, Milan, Italy.
- Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam, the Netherlands.
ORCID-Profile: Alessandra Riva, Giulia Pasqualin, Francesco Sturla, Lara Tondi, Simone Saitta, Davide Tondi, Jessica Zannoni, Giandomenico Disabato, Daniel Giese, Massimo Chessa, Pietro Spagnolo, Alberto Redaelli, Massimo Lombardi, Emiliano Votta
Förderung
- Italian Ministry of Health (Ricerca Corrente)
- Ministero della Salute
Zitieren
APA
Riva, A., Pasqualin, G., Sturla, F., Tondi, L., Saitta, S., Tondi, D., Zannoni, J., Disabato, G., Giese, D., Chessa, M., Spagnolo, P., Redaelli, A., Lombardi, M., & Votta, E. (2026). 4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70493
Vancouver
Riva A, Pasqualin G, Sturla F, Tondi L, Saitta S, Tondi D, et al. 4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70493
BibTeX
@article{Riva2026,
author = {Riva, Alessandra and Pasqualin, Giulia and Sturla, Francesco and Tondi, Lara and Saitta, Simone and Tondi, Davide and Zannoni, Jessica and Disabato, Giandomenico and Giese, Daniel and Chessa, Massimo and Spagnolo, Pietro and Redaelli, Alberto and Lombardi, Massimo and Votta, Emiliano},
title = {4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70493}
}
EUVIMED