EUVIMEDEUVIMED entdecken
Open Access

4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability

Alessandra Riva iD, Giulia Pasqualin iD, Francesco Sturla iD, Lara Tondi iD, Simone Saitta iD, Davide Tondi iD, Jessica Zannoni iD, Giandomenico Disabato iD, Daniel Giese iD, Massimo Chessa iD, Pietro Spagnolo iD, Alberto Redaelli iD und 2 weitere

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70493 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Alessandra Riva und 13 weiteren Autor:innen. Beteiligte Einrichtung: 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, San Donato Milanese, Italy. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Image Interpretation, Computer-Assisted, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Italian Ministry of Health (Ricerca Corrente), Ministero della Salute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To address limitations in tricuspid regurgitation (TR) quantification by magnetic resonance imaging (MRI) or transthoracic echocardiography (TTE), a new method is proposed to directly quantify TR volume (TR V ) using 4D Flow MRI with retrospective tricuspid valve (TV) annular tracking.

Methods

Thirty patients with TR were prospectively enrolled. TR V was quantified using four MRI‐based methods: (i) indirect, (ii) direct (2D phase‐contrast), (iii) 4D Flow with a static TV plane, and (iv) 4D Flow with dynamic annular tracking. Reproducibility and agreement were assessed in terms of TR grading against standard MRI‐ and TTE‐based methods.

Results

The dynamic 4D Flow method correlated strongly with all other MRI methods ( r = 0.77–0.81, p < 0.0001) but consistently yielded higher TR V values. Compared with the indirect method, it showed a Bland–Altman bias of 16 mL (limits of agreement: −19 to 51 mL), along with the highest agreement (intraclass correlation coefficient of 0.88). Agreement in TR severity grading was poor across methods (kappa ≤ 0.07), with dynamic 4D Flow classifying more cases as moderate or severe. Agreement with TTE was slight (kappa = 0.17, p = 0.27) with concordant TR grading in 50% of patients. Inter‐observer reproducibility was excellent ( r = 0.99, bias = 0.7 mL, kappa = 0.80).

Conclusion

4D Flow with dynamic TV tracking offers a reproducible and potentially more sensitive method for TR V quantification than conventional MRI techniques. Despite limited alignment with TTE, this technique may help overcome key imaging limitations and improve TR clinical evaluation, especially in complex cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tricuspid Valve InsufficiencyImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingHumansReproducibility of ResultsFemaleSensitivity and SpecificityMaleMiddle AgedImage EnhancementAgedAlgorithmsAdultBlood Flow Velocity

Autor:innen und Institutionen

  • 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, San Donato Milanese, Italy.
  • Pediatric and Adult Congenital Disease Heart Centre, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Department of Radiology, IRCCS Foundation Ca' Granda Ospedale Maggiore Policlinico, University of Milan, Milan, Italy.
  • Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam, the Netherlands.

ORCID-Profile: Alessandra Riva, Giulia Pasqualin, Francesco Sturla, Lara Tondi, Simone Saitta, Davide Tondi, Jessica Zannoni, Giandomenico Disabato, Daniel Giese, Massimo Chessa, Pietro Spagnolo, Alberto Redaelli, Massimo Lombardi, Emiliano Votta

Förderung

  • Italian Ministry of Health (Ricerca Corrente)
  • Ministero della Salute

Zitieren

APA

Riva, A., Pasqualin, G., Sturla, F., Tondi, L., Saitta, S., Tondi, D., Zannoni, J., Disabato, G., Giese, D., Chessa, M., Spagnolo, P., Redaelli, A., Lombardi, M., & Votta, E. (2026). 4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70493

Vancouver

Riva A, Pasqualin G, Sturla F, Tondi L, Saitta S, Tondi D, et al. 4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70493

BibTeX
@article{Riva2026,
  author = {Riva, Alessandra and Pasqualin, Giulia and Sturla, Francesco and Tondi, Lara and Saitta, Simone and Tondi, Davide and Zannoni, Jessica and Disabato, Giandomenico and Giese, Daniel and Chessa, Massimo and Spagnolo, Pietro and Redaelli, Alberto and Lombardi, Massimo and Votta, Emiliano},
  title = {4D Flow MRI ‐Based Quantification of Tricuspid Regurgitation: A Possible Approach to Improve Measurement Repeatability},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70493}
}