Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70297 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Wilhelm Stehling und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Image Interpretation, Computer-Assisted, Imaging, Three-Dimensional, Adipose Tissue. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health˜Holland, Health~Holland.
Abstract (Originalsprache)
Purpose
To develop and validate a protocol for simultaneous volumetric T1 and T2 mapping with blood‐ and fat‐suppression, and apply it to patients with abdominal aortic aneurysms (AAA) to assess tissue characteristics.
Methods
A spoiled gradient echo (SPGR) variable flip angle (VFA) acquisition was modified with preparation modules to suppress blood and fat signals. To account for the additional T1 and T2 weighting introduced by these preparation blocks, a dedicated signal model was developed, enabling accurate simultaneous T1 and T2 quantification. The method was validated through Bloch simulations and phantom experiments. Subsequently, the protocol was applied to 20 AAA patients.
Results
Bloch simulations perfectly overlaid the signal model, validating the model. In phantom experiments, the bias for T1 was reduced from −781 to 100 ms when incorporating the signal model, and the bias for T2 was −7 ms. In vivo application in 20 AAA patients demonstrated the feasibility of generating volumetric T1 and T2 maps of the aortic vessel wall with blood‐ and fat‐suppression.
Conclusion
The proposed method enables simultaneous T1 and T2 mapping with blood‐ and fat‐suppression in AAA patients. Validation in simulations and phantom experiments confirmed accuracy, while in vivo experiments demonstrated technical feasibility, providing a foundation for future clinical studies on vessel wall tissue characterization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands.
- Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands.
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, the Netherlands.
- Vascular Surgery, Amsterdam University Medical Center, Amsterdam, the Netherlands.
ORCID-Profile: Wilhelm Stehling, Myrte Wennen, Eva Aalbregt, Eric Schrauben, Pim van Ooij, Kak Khee Yeung, Aart J Nederveen, Oliver J Gurney-Champion
Förderung
- Health˜Holland
- Health~Holland
Zitieren
APA
Stehling, W., Wennen, M., Aalbregt, E., Schrauben, E., van Ooij, P., Yeung, K. K., Nederveen, A. J., & Gurney-Champion, O. J. (2026). Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70297
Vancouver
Stehling W, Wennen M, Aalbregt E, Schrauben E, van Ooij P, Yeung KK, et al. Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70297
BibTeX
@article{Stehling2026,
author = {Stehling, Wilhelm and Wennen, Myrte and Aalbregt, Eva and Schrauben, Eric and van Ooij, Pim and Yeung, Kak Khee and Nederveen, Aart J and Gurney-Champion, Oliver J},
title = {Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70297}
}
EUVIMED