Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70489 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2026. Written by Sune Nørhøj Jespersen and 1 co-authors. Institution: Dept. Clin. Medicine, Aarhus University, Denmark. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Image Enhancement, Image Interpretation, Computer-Assisted. Cited 1 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Crafoord Foundation, Swedish Cancer Society, Lundbeck Foundation.
Abstract (original language)
Purpose
To improve the accuracy of diffusion‐weighted powder average signals for diffusion encoding with arbitrary b‐tensors.
Methods
We identify an intrinsic dihedral () symmetry of diffusion signals for arbitrary diffusion encoding, which defines their natural signal space (a quotient of 3D rotations). Based on this, we propose a method to generate optimal rotation sets that are applied to the diffusion‐encoding gradient waveform to yield powder averages with maximal accuracy. The method, termed “Geometric Filter Optimization” (GFO), amounts to designing a sampling filter that is approximately flat over the relevant part of the associated frequency space. We characterize the filter properties and benchmark performance in terms of the accuracy and precision of powder averages and higher‐order rotational invariants, including comparison with spherical designs and electrostatic‐repulsion‐based designs defined on the same space.
Results
We found that GFO leads to marked improvements in precision and accuracy in powder averaging over diffusion encoding b‐tensors, including axisymmetric and triaxial configurations. For higher‐order rotational invariants, the performance was more nuanced, with GFO, electrostatic repulsion, and spherical designs exhibiting different trade‐offs in bias and precision depending on and .
Conclusion
A fundamental ‐symmetry of tensor‐valued diffusion encoding was shown to constrain its rotational structure and guide the design of optimal rotation sets. This yielded GFO, which provides an efficient recipe for obtaining orientations for powder averaging of signals with axisymmetric and triaxial diffusion encoding. It places no additional demands on gradient system performance and can be used to shorten scan time.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Dept. Clin. Medicine, Aarhus University, Denmark.
- Dept. Physics and Astronomy, Aarhus University, Denmark.
- Dept. of Medical Radiation Physics, Lund University, Sweden.
ORCID profiles: Sune Nørhøj Jespersen, Filip Szczepankiewicz
Funding
- Crafoord Foundation
- Swedish Cancer Society
- Lundbeck Foundation
- Anna-Greta Crafoords Stiftelse för Reumatologisk Forskning
- Cancerfonden
Cite
APA
Jespersen, S. N., & Szczepankiewicz, F. (2026). Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70489
Vancouver
Jespersen SN, Szczepankiewicz F. Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70489
BibTeX
@article{Jespersen2026,
author = {Jespersen, Sune Nørhøj and Szczepankiewicz, Filip},
title = {Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70489}
}
EUVIMED