Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 460-468
DOI: 10.1002/mrm.70346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 19.03.2026. Verfasst von Stefan Kuczera und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Enhancement, Image Interpretation, Computer-Assisted, Prostate. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, Swedish Governmental Funding of Clinical Research (ALF), NCI NIH HHS.
Abstract (Originalsprache)
Purpose
Devising methodology to characterize and optimize acquisition schemes for biological tissues, such as the prostate, that produce model‐based synthetic diffusion‐weighted images and derived model parameters with predictable SNR improvement.
Methods
The averaging effect (AE) in synthetic diffusion‐weighted images obtained through fitting of various signal decay models to signals measured over 21 linearly spaced b‐values between 0 and is determined with analytic expressions. Similarly, the standard deviation of a retrospective 2‐point ADC fit based on the synthetic data is analyzed. Furthermore, acquisition schemes that achieve constant SNR or constant AE for synthetic images over the same b‐value range are devised by means of numerical optimization using either a custom iterative method or a standard function optimizer. These acquisition schemes are verified by measurements on a phantom with a non‐monoexponential diffusion signal decay combined with a bootstrapping approach to increase the number of data samples.
Results
The dependence of AE on model function and parameters is complex. Repeated measurements at specific b‐values can boost AE locally, while improvements in ADC uncertainty are particularly pronounced for repetitions of the higher b‐value. Optimization of acquisition schemes generally results in discrete b‐values, whereby the number of b‐values corresponds to the number of model parameters. Results from phantom measurements are in agreement with the theoretical predictions.
Conclusion
The presented analytical calculations and numerical optimizations can be useful to improve acquisition schemes under various experimental conditions and clinical needs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Department of Radiology, Brigham Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Stefan Kuczera, Stephan E Maier
Förderung
- NIH HHS
- Swedish Governmental Funding of Clinical Research (ALF)
- NCI NIH HHS
- Cancerfonden
- Vetenskapsrådet
- Barncancerfonden
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Kuczera, S., & Maier, S. E. (2026). Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues. Magnetic Resonance in Medicine, 96(1), 460-468. https://doi.org/10.1002/mrm.70346
Vancouver
Kuczera S, Maier SE. Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues. Magnetic Resonance in Medicine. 2026;96(1):460-468. doi:10.1002/mrm.70346
BibTeX
@article{Kuczera2026,
author = {Kuczera, Stefan and Maier, Stephan E},
title = {Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {460--468},
doi = {10.1002/mrm.70346}
}
EUVIMED