EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI

Jordina Aviles Verdera iD, Sara Neves Silva iD, Susanne Schulz-Heise, Sarah McElroy, Mary Rutherford iD, Joseph V Hajnal iD, Raphael Tomi-Tricot, Jana Hutter iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70484 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Jordina Aviles Verdera and 7 co-authors. Institution: Imaging Physics and Engineering Research Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Fetus, Prenatal Diagnosis. 22 references. The full text is freely available (open access, CC BY 4.0). Funded by: Deutsche Forschungsgemeinschaft, Lower Saxony Ministry of Science and Culture, European Research Council.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop and evaluate a real‐time framework for targeted slice‐level reacquisition in fetal diffusion MRI.

Methods

A DW‐SE‐EPI sequence was modified to support independent diffusion preparation per slice. A pathology‐robust nnU‐Net segmentation network, updated from a previously published baseline (V1) using pathological fetal cases and physics‐inspired augmentation (V2), and intensity‐based artifact detection drive automated reacquisition prioritization. Retrospective validation was performed on 60 cases across three cohorts at two field strengths and prospective deployment in 14 cases at two clinical sites.

Results

Segmentation V2 significantly outperformed V1 across all cohorts (), with largest gains at b0 s mm (median DSC gain 0.87 at 1.5 T). Blackout detection achieved F1 = 0.81 0.29 at T = 0.35. Prospective real‐time deployment confirmed clinical feasibility at both field strengths.

Conclusion

Real‐time slice‐level fetal diffusion reacquisition is demonstrated for the first time, opening a pathway toward routine quantitative fetal diffusion MRI in research and clinical settings.

Subjects

MeSH terms (MEDLINE)

Diffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedFetusPrenatal DiagnosisHumansArtifactsFemaleAlgorithmsMotionPregnancyBrainRetrospective StudiesReproducibility of Results

Author keywords

artifact detectionbrain segmentationfetal diffusion MRIreal‐time reacquisition

Authors and institutions

  • Imaging Physics and Engineering Research Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • Institute for Information Processing, Leibniz University Hannover, Hannover, Germany.
  • CAIMed, L3S Research Center, Hannover, Germany.
  • Radiology Institute, Uniklinikum Erlangen, Erlangen, Germany.
  • Early Life Imaging Department, School of Biomedical Engineering and Imaging Sciences, King's college, London, UK.
  • MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.

ORCID profiles: Jordina Aviles Verdera, Sara Neves Silva, Mary Rutherford, Joseph V Hajnal, Jana Hutter

Funding

  • Deutsche Forschungsgemeinschaft
  • Lower Saxony Ministry of Science and Culture
  • European Research Council
  • Medical Research Council

Cite

APA

Aviles Verdera, J., Neves Silva, S., Schulz-Heise, S., McElroy, S., Rutherford, M., Hajnal, J. V., Tomi-Tricot, R., & Hutter, J. (2026). Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70484

Vancouver

Aviles Verdera J, Neves Silva S, Schulz-Heise S, McElroy S, Rutherford M, Hajnal JV, et al. Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70484

BibTeX
@article{AvilesVerdera2026,
  author = {Aviles Verdera, Jordina and Neves Silva, Sara and Schulz-Heise, Susanne and McElroy, Sarah and Rutherford, Mary and Hajnal, Joseph V and Tomi-Tricot, Raphael and Hutter, Jana},
  title = {Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70484}
}
Start for free →