EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

T1 ‐weighting in Steady‐State FLASH MRI –Diffusion Is Not Only Supportive but Mandatory for the Contrast

Simon Weinmüller iD, Deepak Charles Chellapandian, Jonathan Endres iD, Jochen Leupold iD, Florian Gritsch, Fabian Wagner, Rainer Schneider iD, Moritz Zaiss

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1789-1797

DOI: 10.1002/mrm.70443 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-06-21. Written by Simon Weinmüller and 7 co-authors. Institution: Institute of Neuroradiology, Uniklinikum Erlangen, Erlangen, Germany. Major MEDLINE topics: Brain, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. 46 references. The full text is freely available (open access, CC BY 4.0). Funded by: d.hip Campus - Bavarian AIM, Deutsche Forschungsgemeinschaft, Bundesministerium für Bildung und Forschung.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

FLASH imaging is widely assumed to produce a T 1 ‐weighted steady‐state contrast using RF‐ and gradient‐spoiling. We observed substantial overestimation of CSF signals in simulations, when diffusion was neglected and realistic proton density was applied. This work investigates the role of diffusion in steady‐state FLASH contrast formation and its implications for simulation‐based modeling and measurement.

Methods

FLASH sequences were simulated using phase graph simulations using a synthetic brain phantom with and without diffusion and realistic PD values to show the contrast change. The impact of neglecting diffusion in synthetic training data was evaluated using a segmentation network trained on simulated data and tested on in vivo measurement. Experimental validation of the contrast change was performed using a 3D‐printed brain phantom using silicone oil as a low‐diffusivity compartment.

Results

Without diffusion, simulations showed CSF signal intensities higher than WM, resulting in a contrast change. Diffusion suppresses higher‐order echoes in long T 2 tissues and is essential for achieving the T 1 ‐weighted steady‐state contrast. A NN trained without diffusion fails to generalize to in vivo data and measurements with silicone oil compartments confirm the contrast changes in low‐diffusivity media.

Conclusion

Diffusion is essential for realistic FLASH simulations of long T 2 tissues such as CSF. Steady‐state FLASH contrast arises from the interplay of RF‐, gradient‐spoiling, and “multi‐TR‐relaxation‐spoiling” governed by T 2 ‐decay and diffusion effects. For many quadratic phase cycling schemes, diffusion is required to obtain realistic T 1 ‐weighted contrast in MR simulations and should not be neglected in simulations or simulation‐based deep learning applications.

Subjects

MeSH terms (MEDLINE)

BrainDiffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingComputer SimulationHumansAlgorithmsDiffusionPrinting, Three-DimensionalSilicone OilsCerebrospinal Fluid

Author keywords

RF‐spoilingT1‐weighted FLASHTR‐spoilingdiffusiongradient‐spoilingsteady‐state

Substances

Silicone Oils

Authors and institutions

  • Institute of Neuroradiology, Uniklinikum Erlangen, Erlangen, Germany.
  • Department of Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
  • Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

ORCID profiles: Simon Weinmüller, Jonathan Endres, Jochen Leupold, Rainer Schneider

Funding

  • d.hip Campus - Bavarian AIM
  • Deutsche Forschungsgemeinschaft
  • Bundesministerium für Bildung und Forschung
  • Competence Network for Scientific High Performance Computing in Bavaria (KONWIHR)

Cite

APA

Weinmüller, S., Chellapandian, D. C., Endres, J., Leupold, J., Gritsch, F., Wagner, F., Schneider, R., & Zaiss, M. (2026). T1 ‐weighting in Steady‐State FLASH MRI –Diffusion Is Not Only Supportive but Mandatory for the Contrast. Magnetic Resonance in Medicine, 96(4), 1789-1797. https://doi.org/10.1002/mrm.70443

Vancouver

Weinmüller S, Chellapandian DC, Endres J, Leupold J, Gritsch F, Wagner F, et al. T1 ‐weighting in Steady‐State FLASH MRI –Diffusion Is Not Only Supportive but Mandatory for the Contrast. Magnetic Resonance in Medicine. 2026;96(4):1789-1797. doi:10.1002/mrm.70443

BibTeX
@article{Weinmller2026,
  author = {Weinmüller, Simon and Chellapandian, Deepak Charles and Endres, Jonathan and Leupold, Jochen and Gritsch, Florian and Wagner, Fabian and Schneider, Rainer and Zaiss, Moritz},
  title = {T1 ‐weighting in Steady‐State FLASH MRI –Diffusion Is Not Only Supportive but Mandatory for the Contrast},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1789--1797},
  doi = {10.1002/mrm.70443}
}
Start for free →