Simultaneous multislice diffusion imaging using navigator‐free multishot spiral acquisitions
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30427 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yuancheng Jiang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 80 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
Purpose
This work aims to raise a novel design for navigator‐free multiband (MB) multishot uniform‐density spiral (UDS) acquisition and reconstruction, and to demonstrate its utility for high‐efficiency, high‐resolution diffusion imaging. Theory and Methods Our design focuses on the acquisition and reconstruction of navigator‐free MB multishot UDS diffusion imaging. For acquisition, radiofrequency‐pulse encoding was used to achieve controlled aliasing in parallel imaging in MB imaging. For reconstruction, a new algorithm named slice–projection onto convex sets–enhanced inherent correction of phase errors (slice‐POCS‐ICE) was proposed to simultaneously estimate diffusion‐weighted images and intershot phase variations for each slice. The efficacy of the proposed methods was evaluated in both numerical simulation and in vivo experiments.
Results
In both numerical simulation and in vivo experiments, slice‐POCS‐ICE estimated phase variations more precisely and provided results with better image quality than other methods. The intershot phase variations and MB slice aliasing artifacts were simultaneously resolved using the proposed slice‐POCS‐ICE algorithm.
Conclusion
The proposed navigator‐free MB multishot UDS acquisition and reconstruction method is an effective solution for high‐efficiency, high‐resolution diffusion imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
ORCID-Profile: Yuancheng Jiang, Xin Shao, Hua Guo
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Jiang, Y., Li, G., Shao, X., & Guo, H. (2025). Simultaneous multislice diffusion imaging using navigator‐free multishot spiral acquisitions. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30427
Vancouver
Jiang Y, Li G, Shao X, Guo H. Simultaneous multislice diffusion imaging using navigator‐free multishot spiral acquisitions. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30427
BibTeX
@article{Jiang2025,
author = {Jiang, Yuancheng and Li, Guangqi and Shao, Xin and Guo, Hua},
title = {Simultaneous multislice diffusion imaging using navigator‐free multishot spiral acquisitions},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30427}
}
EUVIMED