EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI

Christoph A Rettenmeier iD, Zidan Yu, Krystalyn Edwards-Calma iD, Kai Tobias Block, V Andrew Stenger

Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1245-1260

DOI: 10.1002/mrm.70433 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.05.2026. Verfasst von Christoph A Rettenmeier und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a novel single‐shot radial echo planar imaging (ss‐rEPI) technique for rapid, distortion‐free brain imaging in functional MRI experiments.

Methods

Radial multi‐gradient echo (radial mGRE) data were acquired on a 3T clinical scanner using a 2D ss‐rEPI readout with small golden‐angle rotations between echoes. Images were reconstructed using an iterative conjugate‐gradient method incorporating coil sensitivities, B 0 field inhomogeneities, transverse relaxation, and field‐drift correction to account for signal inconsistencies in the extended mGRE readout. Additional k ‐space‐weighted image contrast (KWIC) filtering prior to reconstruction helped reduce model mismatches at low spatial frequencies. Single‐shot rEPI image quality, contrast, and distortion were assessed against multi‐shot radial mGRE reference data. Retrospective adjustment of the KWIC filter and target TE in the reconstruction allowed the generation of multiple T 2 *weighted and phase contrast images from a single ss‐rEPI scan, enabling quantitative T 2 * mapping and QSM. Visual BOLD fMRI experiments were conducted and evaluated against Cartesian EPI measurements.

Results

Twenty‐four 3 mm thick slices of distortion‐free, multi‐contrast brain images were obtained at 2 × 2 and 1.5 mm 2 (ramp‐sampled) in‐plane resolution with an acquisition time of under 1.7 s. In multi‐session fMRI experiments on two subjects, ss‐rEPI demonstrated BOLD activation in the visual cortex comparable to standard EPI while also enabling functional T 2 * measurements.

Conclusion

Single‐shot rEPI enables rapid, distortion‐free 2D multi‐contrast brain imaging, offering a promising alternative to Cartesian EPI. Accurate ∆ B 0 modeling is critical for ss‐rEPI performance. Advanced reconstruction techniques and self‐calibration methods could further enhance its speed, performance, and applicability across diverse MRI techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingBrainMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansAlgorithmsBrain MappingMaleAdultFemale

Stichwörter der Autor:innen

BOLD fMRIKWICfast multi‐contrast imagingmulti‐echoradial EPIsingle‐shot

Autor:innen und Institutionen

  • Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA.
  • Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.

ORCID-Profile: Christoph A Rettenmeier, Krystalyn Edwards-Calma

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Rettenmeier, C. A., Yu, Z., Edwards-Calma, K., Block, K. T., & Stenger, V. A. (2026). Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI. Magnetic Resonance in Medicine, 96(3), 1245-1260. https://doi.org/10.1002/mrm.70433

Vancouver

Rettenmeier CA, Yu Z, Edwards-Calma K, Block KT, Stenger VA. Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI. Magnetic Resonance in Medicine. 2026;96(3):1245-1260. doi:10.1002/mrm.70433

BibTeX
@article{Rettenmeier2026,
  author = {Rettenmeier, Christoph A and Yu, Zidan and Edwards-Calma, Krystalyn and Block, Kai Tobias and Stenger, V Andrew},
  title = {Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1245--1260},
  doi = {10.1002/mrm.70433}
}
Kostenlos starten →