EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation

Yuliang Xiao iD, Jason Rock iD, Zhe Wu iD, Jamie Near iD, Mark Chiew iD, Simon J Graham iD

Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1219-1234

DOI: 10.1002/mrm.70431 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 14.05.2026. Verfasst von Yuliang Xiao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, CIHR, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To introduce SelExNet: a self‐supervised framework for two‐dimensional spatially selective excitation that jointly optimizes radiofrequency (RF) pulses and gradient waveforms, and extends to multi‐channel transmission MRI.

Methods

Building on prior RF‐only and joint RF‐gradient optimization approaches, SelExNet couples neural RF and gradient generators with a differentiable Bloch simulator to enable self‐supervised pulse optimization without requiring pre‐designed target pulses. The framework jointly designs RF pulses and parameterized variable‐density spiral gradient waveforms for both single‐ and multi‐channel transmission, with patient‐specific adaptation using measured, previously unseen and maps.

Results

Joint optimization of RF and gradients improved excitation fidelity compared to RF‐only optimization. In phantom experiments with synthetic field maps, pretrained pulses showed distortions, whereas fine‐tuned pulses restored geometry and uniformity. In vivo studies demonstrated anatomically precise excitation, with fine‐tuning improving sharpness and reducing off‐target signal.

Conclusion

The proposed framework enables joint RF‐gradient design and extends self‐supervised pulse optimization to multi‐channel transmission MRI. SelExNet achieves high‐fidelity, anatomically precise excitation and demonstrates robustness to field inhomogeneities, offering a scalable pathway for ultra‐high field imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedBrainPhantoms, ImagingAlgorithmsRadio WavesHumans

Stichwörter der Autor:innen

Bloch equationsRF pulsejoint optimizationmulti‐channel transmitself‐supervised learningvariable‐density spiral trajectory

Autor:innen und Institutionen

  • Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
  • Siemens Healthcare Limited, Oakville, Ontario, Canada.

ORCID-Profile: Yuliang Xiao, Jason Rock, Zhe Wu, Jamie Near, Mark Chiew, Simon J Graham

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • CIHR
  • Canadian Institutes of Health Research

Zitieren

APA

Xiao, Y., Rock, J., Wu, Z., Near, J., Chiew, M., & Graham, S. J. (2026). SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation. Magnetic Resonance in Medicine, 96(3), 1219-1234. https://doi.org/10.1002/mrm.70431

Vancouver

Xiao Y, Rock J, Wu Z, Near J, Chiew M, Graham SJ. SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation. Magnetic Resonance in Medicine. 2026;96(3):1219-1234. doi:10.1002/mrm.70431

BibTeX
@article{Xiao2026,
  author = {Xiao, Yuliang and Rock, Jason and Wu, Zhe and Near, Jamie and Chiew, Mark and Graham, Simon J},
  title = {SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1219--1234},
  doi = {10.1002/mrm.70431}
}