EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T

Timothy Anderson iD, Niklas Wallstein, Lucas Soustelle iD, Thomas Troalen iD, Gopal Varma iD, David C Alsop, Maxime Guye, Guillaume Duhamel, Olivier M Girard iD

Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1162-1177

DOI: 10.1002/mrm.70419 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-05-11. Written by Timothy Anderson and 8 co-authors. Institution: Aix Marseille Univ, CNRS, CRMBM, Marseille, France. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. 45 references. The full text is freely available (open access, CC BY 4.0). Funded by: A*MIDEX, Agence Nationale de la Recherche, France Life Imaging.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

Inhomogeneous MT (ihMT) is an MRI modality sensitive to Myelin, the lipid‐rich membrane surrounding the axons. A novel ihMT saturation strategy and its associated correction at UHF are proposed. The aim is to generate a strong ihMT effect within a clinically compatible scan time while complying with SAR constraints at 7 T.

Methods

The MT preparation module of the proposed approach was shortened, reducing power deposition and allowing for shorter scan time while maximizing SNR efficiency. Optimization of the sequence was validated on (2 mm iso.) on a 7 T clinical scanner. Example high resolution images were acquired (1–1.4 mm iso.). Model‐based corrections were applied and their impact on ihMT quantification was studied. Numerical simulations and error quantifications were performed to complement experimental data.

Results

Fewer bursts () of cosine‐modulated MT preparation pulses () performed at maximal yielded strong ihMT signal with better SNR efficiency as compared to previously proposed long saturation trains (). correction showed a reliability range () which challenged applicability in strong hypo‐intense areas. High resolution acquisitions showed acceptable SNR () for resolutions down to 1 mm iso., enabling studies of fine structures (e.g., deep gray nuclei) with added specificity provided by ihMT. Conclusion ihMT applications at 7 T are enabled. While whole‐brain imaging requires further work to compensate for inhomogeneities, localized applications (e.g., Thalamus) are immediately feasible within clinically compatible scan time (< min). Similar sequence improvements are expected at lower field strengths (e.g., ).

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedBrainHumansReproducibility of ResultsAlgorithmsSignal-To-Noise RatioComputer SimulationMyelin SheathPhantoms, ImagingImage Enhancement

Author keywords

UHFhigh resolutioninhomogenous magnetization transfer B 1 + correctionmyelinneuroimaging

Authors and institutions

  • Aix Marseille Univ, CNRS, CRMBM, Marseille, France.
  • APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France.
  • Siemens Healthcare SAS, Courbevoie, France.
  • Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.

ORCID profiles: Timothy Anderson, Lucas Soustelle, Thomas Troalen, Gopal Varma, Olivier M Girard

Funding

  • A*MIDEX
  • Agence Nationale de la Recherche
  • France Life Imaging
  • France Sclérose en Plaques

Cite

APA

Anderson, T., Wallstein, N., Soustelle, L., Troalen, T., Varma, G., Alsop, D. C., Guye, M., Duhamel, G., & Girard, O. M. (2026). SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T. Magnetic Resonance in Medicine, 96(3), 1162-1177. https://doi.org/10.1002/mrm.70419

Vancouver

Anderson T, Wallstein N, Soustelle L, Troalen T, Varma G, Alsop DC, et al. SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T. Magnetic Resonance in Medicine. 2026;96(3):1162-1177. doi:10.1002/mrm.70419

BibTeX
@article{Anderson2026,
  author = {Anderson, Timothy and Wallstein, Niklas and Soustelle, Lucas and Troalen, Thomas and Varma, Gopal and Alsop, David C and Guye, Maxime and Duhamel, Guillaume and Girard, Olivier M},
  title = {SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1162--1177},
  doi = {10.1002/mrm.70419}
}
Start for free →