Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors
Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1502-1517
DOI: 10.1002/mrm.70418 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-05-10. Written by Conner S Ubert and 8 co-authors. Institution: Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA. Major MEDLINE topics: Oximetry, Oxygen, Magnetic Resonance Imaging. 65 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, NIGMS NIH HHS, Dartmouth Cancer Center "Big-bet".
Abstract (original language)
Purpose
Tumor hypoxia remains a major barrier to effective radiation therapy, yet no current imaging technique can generate spatially resolved, absolute pO 2 maps with sufficient depth penetration and spatial resolution for clinical use. This study introduces quantitative oxygen‐enhanced MRI (qOE‐MRI), a multimodal approach integrating electron paramagnetic resonance (EPR) oximetry using the OxyChip with oxygen‐enhanced MRI to enable high‐resolution mapping of absolute tumor pO 2 .
Methods
Phantom studies at 9.4 T validated the linearity of the R 1 –pO 2 relationship using saturation‐recovery T 1 mapping across known oxygen concentrations. OxyChip sensors coated with gold nanoparticles were used for EPR oximetry. In vivo qOE‐MRI was evaluated and tested in an SCC7 mouse tumor model by combining L‐band EPR oximetry under normoxic and hyperoxic breathing with quantitative T 1 mapping at 9.4 T. Tissue‐specific R 1 versus pO 2 calibration was established using EPR‐derived pO 2 measurements at implanted OxyChip locations and applied voxel‐wise to generate spatial pO 2 maps.
Results
Phantom validation demonstrated excellent R 1 –pO 2 linearity ( R 2 = 0.999) with predictive precision of 2.6 mmHg. OxyChip characterization confirmed robust oxygen sensitivity (12.6 mG/mmHg) and MRI visibility with gold coating. In vivo calibration showed a strong R 1 –pO 2 correlation ( R 2 = 0.9737). Resulting pO 2 maps revealed marked intratumoral heterogeneity: the hypoxic core on average showed no increase in oxygenation due to hyperoxygenation, whereas peripheral and muscle‐adjacent regions exhibited increased oxygenation. Conclusion qOE‐MRI enables repeatable and spatially resolved absolute tumor pO 2 mapping. By combining OxyChip technology, clinical EPR systems, and standard MRI platforms, this approach holds promise for translation into hypoxia‐guided radiation therapy planning.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
- Department of Psychiatry, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
- Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
- Department of Radiation Oncology and Applied Sciences, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
ORCID profiles: Conner S Ubert, Periannan Kuppusamy
Funding
- NCI NIH HHS
- NIGMS NIH HHS
- Dartmouth Cancer Center "Big-bet"
- NIBIB NIH HHS
- NIH HHS
- Geisel School of Medicine at Dartmouth DCC Irradiation, Imaging, Microscopy and Animal Cancer Models Core Facility
- National Institutes of Health
Cite
APA
Ubert, C. S., Kassey, V. B., Kmiec, M. M., Wallin, D. J., Kheirollah, A., Petryakov, S. V., O'Connell, R. C., Schaner, P. E., & Kuppusamy, P. (2026). Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors. Magnetic Resonance in Medicine, 96(3), 1502-1517. https://doi.org/10.1002/mrm.70418
Vancouver
Ubert CS, Kassey VB, Kmiec MM, Wallin DJ, Kheirollah A, Petryakov SV, et al. Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors. Magnetic Resonance in Medicine. 2026;96(3):1502-1517. doi:10.1002/mrm.70418
BibTeX
@article{Ubert2026,
author = {Ubert, Conner S and Kassey, Victor B and Kmiec, Maciej M and Wallin, Diana J and Kheirollah, Alireza and Petryakov, Sergey V and O'Connell, Ryan C and Schaner, Philip E and Kuppusamy, Periannan},
title = {Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {3},
pages = {1502--1517},
doi = {10.1002/mrm.70418}
}
EUVIMED