Hand‐held electron spin resonance scanner for subcutaneous oximetry using OxyChip
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Nir Almog und 6 weiteren Autor:innen. Beteiligte Einrichtung: Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel. Hauptthemen laut MEDLINE: Phantoms, Imaging, Oximetry, Oxygen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
Electron spin resonance (ESR) is used to measure oxygen partial pressure (pO 2 ) in biological media with many clinical applications. Traditional clinical ESR involves large magnets that encompass the subject of measurement. However, certain applications might benefit from a scanner operating within local static magnetic fields. Our group recently developed such a compact scanner for transcutaneous (surface) pO 2 measurements of skin tissue. Here we extend this capability to subsurface (subcutaneous) pO 2 measurements and verify it using an artificial tissue emulating (ATE) phantom.
Methods
We introduce a new scanner, tailored for subcutaneous measurements up to 2 mm beneath the skin's surface. This scanner captures pulsed ESR signals from embedded approximate 1‐mm oxygen‐sensing solid paramagnetic implant, OxyChip. The scanner features a static magnetic field source, producing a uniform region outside its surface, and a compact microwave resonator, for exciting and receiving ESR signals.
Results
ESR readings derived from an OxyChip, positioned approximately 1.5 mm from the scanner's surface, embedded in ATE phantom, exhibited a linear relation of 1/T 2 versus pO 2 for pO 2 levels at 0, 7.6, 30, and 160 mmHg, with relative reading accuracy of about 10%.
Conclusion
The compact ESR scanner can report pO 2 data in ATE phantom from an external position relative to the scanner. Implementing this scanner in preclinical and clinical applications for subcutaneous pO 2 measurements is a feasible next phase for this development. This innovative design also has the potential to operate in conjunction with artificial skin graft for wound healing, combining therapeutic and pO 2 diagnostic features.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel.
- Department of Radiology, Radiation Oncology, and Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.
- Faculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
ORCID-Profile: Periannan Kuppusamy, Aharon Blank
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Almog, N., Zgadzai, O., Kuppusamy, P., Zur, Y., Baruch, L., Machluf, M., & Blank, A. (2024). Hand‐held electron spin resonance scanner for subcutaneous oximetry using OxyChip. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30066
Vancouver
Almog N, Zgadzai O, Kuppusamy P, Zur Y, Baruch L, Machluf M, et al. Hand‐held electron spin resonance scanner for subcutaneous oximetry using OxyChip. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30066
BibTeX
@article{Almog2024,
author = {Almog, Nir and Zgadzai, Oleg and Kuppusamy, Periannan and Zur, Yehonatan and Baruch, Limor and Machluf, Marcelle and Blank, Aharon},
title = {Hand‐held electron spin resonance scanner for subcutaneous oximetry using OxyChip},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30066}
}
EUVIMED