EUVIMEDEUVIMED entdecken
Open Access

Evaluation of a deuterated triarylmethyl spin probe for in vivo R 2 ∗ ‐based EPR oximetric imaging with enhanced dynamic range

Shun Kishimoto iD, Nallathamby Devasahayam, Gadisetti V R Chandramouli, Ramachandran Murugesan, Yasunori Otowa, Kota Yamashita, Kazutoshi Yamamoto, Jeffrey R Brender, Murali C Krishna

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29811 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Shun Kishimoto und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Biology Branch, Center for Cancer Research, NCI, Bethesda, Maryland, USA. Hauptthemen laut MEDLINE: Oximetry, Neoplasms. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

In this study, we compared two triarylmethyl (TAM) spin probes, Ox071 and Ox063 for their efficacy in measuring tissue oxygen levels under hypoxic and normoxic conditions by R 2 * ‐based EPR oximetry.

Methods

The R 2 * dependencies on the spin probe concentration and oxygen level were calibrated using deoxygenated 1, 2, 5, and 10 mM standard solutions and 2 mM solutions saturated at 0%, 2%, 5%, 10%, and 21% of oxygen. For the hypoxic model, in vivo imaging of a MIA PaCa‐2 tumor implanted in the hind leg of a mouse was performed on successive days by R 2 * ‐based EPR oximetry using either Ox071 or Ox063. For the normoxic model, renal imaging of healthy athymic mice was performed using both spin probes. The 3D images were reconstructed by single point imaging and multi‐gradient technique was used to determine R 2 * maps.

Results

The signal intensities of Ox071 were approximately three times greater than that of Ox063 in the entire partial pressure of oxygen ( pO 2 ) range investigated. The histograms of the tumor pO 2 images were skewed for both spin probes, and Ox071 showed more frequency counts at pO 2 > 32 mm Hg. In the normoxic kidney model, there was a clear delineation between the high pO 2 cortex and the low pO 2 medulla regions. The histogram of high‐resolution kidney oximetry image using Ox071 was nearly symmetrical and frequency counts were seen up to 55 mm Hg, which were missed in Ox063 imaging.

Conclusion

As an oximetric probe, Ox071 has clear advantages over Ox063 in terms of sensitivity and the pO 2 dynamic range.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetryNeoplasmsMiceAnimalsElectron Spin Resonance SpectroscopyOxygenImaging, Three-Dimensional

Stichwörter der Autor:innen

FT-EPRIOx071TD EPRIkidney imagingoximetrypO2 dynamic range

Substanzen

Oxygen

Autor:innen und Institutionen

  • Radiation Biology Branch, Center for Cancer Research, NCI, Bethesda, Maryland, USA.
  • Urologic Oncology Branch, Center for Cancer Research, NCI, Bethesda, Maryland, USA.
  • GenEpria Consulting Inc., Columbia, Maryland, USA.
  • Karpaga Vinayaga Institute of Medical Sciences and Research Center, Chengalpattu, Tamil Nadu, India.

ORCID-Profile: Shun Kishimoto

Förderung

  • Intramural NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Kishimoto, S., Devasahayam, N., Chandramouli, G. V. R., Murugesan, R., Otowa, Y., Yamashita, K., Yamamoto, K., Brender, J. R., & Krishna, M. C. (2024). Evaluation of a deuterated triarylmethyl spin probe for in vivo R 2 ∗ ‐based EPR oximetric imaging with enhanced dynamic range. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29811

Vancouver

Kishimoto S, Devasahayam N, Chandramouli GVR, Murugesan R, Otowa Y, Yamashita K, et al. Evaluation of a deuterated triarylmethyl spin probe for in vivo R 2 ∗ ‐based EPR oximetric imaging with enhanced dynamic range. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29811

BibTeX
@article{Kishimoto2024,
  author = {Kishimoto, Shun and Devasahayam, Nallathamby and Chandramouli, Gadisetti V R and Murugesan, Ramachandran and Otowa, Yasunori and Yamashita, Kota and Yamamoto, Kazutoshi and Brender, Jeffrey R and Krishna, Murali C},
  title = {Evaluation of a deuterated triarylmethyl spin probe for in vivo R 2 ∗ ‐based EPR oximetric imaging with enhanced dynamic range},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29811}
}
Kostenlos starten →