EUVIMEDEUVIMED entdecken
Open Access

Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors

Conner S Ubert iD, Victor B Kassey, Maciej M Kmiec, Diana J Wallin, Alireza Kheirollah, Sergey V Petryakov, Ryan C O'Connell, Philip E Schaner, Periannan Kuppusamy iD

Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1502-1517

DOI: 10.1002/mrm.70418 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 10.05.2026. Verfasst von Conner S Ubert und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA. Hauptthemen laut MEDLINE: Oximetry, Oxygen, Magnetic Resonance Imaging. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIGMS NIH HHS, Dartmouth Cancer Center "Big-bet".

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Tumor hypoxia remains a major barrier to effective radiation therapy, yet no current imaging technique can generate spatially resolved, absolute pO 2 maps with sufficient depth penetration and spatial resolution for clinical use. This study introduces quantitative oxygen‐enhanced MRI (qOE‐MRI), a multimodal approach integrating electron paramagnetic resonance (EPR) oximetry using the OxyChip with oxygen‐enhanced MRI to enable high‐resolution mapping of absolute tumor pO 2 .

Methods

Phantom studies at 9.4 T validated the linearity of the R 1 –pO 2 relationship using saturation‐recovery T 1 mapping across known oxygen concentrations. OxyChip sensors coated with gold nanoparticles were used for EPR oximetry. In vivo qOE‐MRI was evaluated and tested in an SCC7 mouse tumor model by combining L‐band EPR oximetry under normoxic and hyperoxic breathing with quantitative T 1 mapping at 9.4 T. Tissue‐specific R 1 versus pO 2 calibration was established using EPR‐derived pO 2 measurements at implanted OxyChip locations and applied voxel‐wise to generate spatial pO 2 maps.

Results

Phantom validation demonstrated excellent R 1 –pO 2 linearity ( R 2 = 0.999) with predictive precision of 2.6 mmHg. OxyChip characterization confirmed robust oxygen sensitivity (12.6 mG/mmHg) and MRI visibility with gold coating. In vivo calibration showed a strong R 1 –pO 2 correlation ( R 2 = 0.9737). Resulting pO 2 maps revealed marked intratumoral heterogeneity: the hypoxic core on average showed no increase in oxygenation due to hyperoxygenation, whereas peripheral and muscle‐adjacent regions exhibited increased oxygenation. Conclusion qOE‐MRI enables repeatable and spatially resolved absolute tumor pO 2 mapping. By combining OxyChip technology, clinical EPR systems, and standard MRI platforms, this approach holds promise for translation into hypoxia‐guided radiation therapy planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetryOxygenMagnetic Resonance ImagingAnimalsElectron Spin Resonance SpectroscopyMicePhantoms, ImagingCell Line, TumorTumor HypoxiaGold

Stichwörter der Autor:innen

EPR oximetryOE‐MRIOxyChipSCC7 tumortumor hypoxia

Substanzen

OxygenGold

Autor:innen und Institutionen

  • Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
  • Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
  • Department of Psychiatry, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
  • Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
  • Department of Radiation Oncology and Applied Sciences, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.

ORCID-Profile: Conner S Ubert, Periannan Kuppusamy

Förderung

  • NCI NIH HHS
  • NIGMS NIH HHS
  • Dartmouth Cancer Center "Big-bet"
  • NIBIB NIH HHS
  • NIH HHS
  • Geisel School of Medicine at Dartmouth DCC Irradiation, Imaging, Microscopy and Animal Cancer Models Core Facility
  • National Institutes of Health

Zitieren

APA

Ubert, C. S., Kassey, V. B., Kmiec, M. M., Wallin, D. J., Kheirollah, A., Petryakov, S. V., O'Connell, R. C., Schaner, P. E., & Kuppusamy, P. (2026). Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors. Magnetic Resonance in Medicine, 96(3), 1502-1517. https://doi.org/10.1002/mrm.70418

Vancouver

Ubert CS, Kassey VB, Kmiec MM, Wallin DJ, Kheirollah A, Petryakov SV, et al. Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors. Magnetic Resonance in Medicine. 2026;96(3):1502-1517. doi:10.1002/mrm.70418

BibTeX
@article{Ubert2026,
  author = {Ubert, Conner S and Kassey, Victor B and Kmiec, Maciej M and Wallin, Diana J and Kheirollah, Alireza and Petryakov, Sergey V and O'Connell, Ryan C and Schaner, Philip E and Kuppusamy, Periannan},
  title = {Combining Oxygen‐Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE ‐ MRI ( qOE ‐ MRI ) as a Method for Mapping Absolute Oxygen Levels ( pO 2 ) in Tumors},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1502--1517},
  doi = {10.1002/mrm.70418}
}
Kostenlos starten →