EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin Algorithm

Moritz Blumenthal iD, Tina Holliber iD, Jonathan I Tamir, Martin Uecker iD

Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1323-1332

DOI: 10.1002/mrm.70416 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-05-10. Written by Moritz Blumenthal and 3 co-authors. Institution: Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria. Major MEDLINE topics: Algorithms, Brain, Image Processing, Computer-Assisted, Diffusion Magnetic Resonance Imaging. 35 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Science Foundation, Austrian Science Fund.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The Unadjusted Langevin Algorithm ( ULA ) in combination with diffusion models can generate high quality MRI reconstructions with uncertainty estimation from highly undersampled k‐space data. However, sampling methods such as diffusion posterior sampling ( DPS ) or likelihood annealing suffer from long reconstruction times and the need for parameter tuning. The purpose of this work is to develop a robust sampling algorithm with fast convergence. Theory and Methods In the reverse diffusion process used for sampling the posterior, the exact likelihood is multiplied with the diffused prior at all noise scales. To overcome the issue of slow convergence, preconditioning is used. The method is trained on fastMRI data and tested on retrospectively undersampled brain data of a healthy volunteer.

Results

For posterior sampling in Cartesian and non‐Cartesian accelerated MRI the new approach outperforms annealed sampling and DPS in terms of reconstruction speed and sample quality.

Conclusion

The proposed exact likelihood with preconditioning enables rapid and reliable posterior sampling across various MRI reconstruction tasks without the need for parameter tuning.

Subjects

MeSH terms (MEDLINE)

AlgorithmsBrainImage Processing, Computer-AssistedDiffusion Magnetic Resonance ImagingMagnetic Resonance ImagingHumansBayes TheoremReproducibility of ResultsImage Enhancement

Author keywords

Bayesian reconstructionMRIdiffusion posterior samplingimage reconstructionparallel imaging

Authors and institutions

  • Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
  • Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, USA.
  • Chandra Family Department of Electrical Engineering, University of Texas at Austin, Austin, USA.
  • Department of Diagnostic Medicine, Dell Medical School, University of Texas at Austin, Austin, USA.
  • BioTechMed-Graz, Graz, Austria.

ORCID profiles: Moritz Blumenthal, Tina Holliber, Martin Uecker

Funding

  • National Science Foundation
  • Austrian Science Fund

Cite

APA

Blumenthal, M., Holliber, T., Tamir, J. I., & Uecker, M. (2026). Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin Algorithm. Magnetic Resonance in Medicine, 96(3), 1323-1332. https://doi.org/10.1002/mrm.70416

Vancouver

Blumenthal M, Holliber T, Tamir JI, Uecker M. Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin Algorithm. Magnetic Resonance in Medicine. 2026;96(3):1323-1332. doi:10.1002/mrm.70416

BibTeX
@article{Blumenthal2026,
  author = {Blumenthal, Moritz and Holliber, Tina and Tamir, Jonathan I and Uecker, Martin},
  title = {Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin Algorithm},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1323--1332},
  doi = {10.1002/mrm.70416}
}
Start for free →