EUVIMEDSkopri EUVIMED
Crossref

Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals ( DIGITAL )

Zhechuan Dai iD, Xiaoxia Wang, Xingwang Yong iD, Jing Zhang, Qing Li, Jiuquan Zhang, Yi Zhang iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 756-770

DOI: 10.1002/mrm.70384 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-04-20. Written by Zhechuan Dai and 6 co-authors. Institution: Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument and Key Laboratory for Biomedical Engineering of Ministry o…. Major MEDLINE topics: Lipids, Magnetic Resonance Imaging, Amides, Image Processing, Computer-Assisted. 64 references. Funded by: National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities, Zhejiang Provincial Natural Science Foundation of China.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

A differential analysis with fitted magnetization transfer and lipid signals (DIGITAL) method is proposed for eliminating fat artifacts and accurately extracting amide proton transfer (APT) contrast in lipid‐rich regions. Theory and Methods The DIGITAL method integrates a two‐pool water‐magnetization transfer (MT) Bloch‐McConnell (BM) model with a six‐peak fat Bloch model. Renormalization is employed to correct fat‐induced Z‐spectrum distortion, and APT # signals are calculated by subtracting the fitted Z‐spectrum from the raw Z‐spectrum. The proposed DIGITAL method was evaluated using numerical simulations, phantoms, and breast tumor data, with its performance compared against prior multi‐pool Lorentzian (MPL) and numerical fitting of extrapolated semisolid magnetization transfer reference signals (NEMR) methods. We also developed a voxel‐wise reliability map to assess data and fit quality.

Results

In simulations and experiments, renormalization effectively corrected fat‐induced signal scaling and restored the Z‐spectrum value at 0 ppm to near 0. The proposed DIGITAL method demonstrated superior uniformity in APT # maps compared to MPL and NEMR. Moreover, DIGITAL was minimally affected by fat, exhibiting high robustness against variations in fat concentrations and a strong linear relationship with amide proton concentrations. In addition, the reliability map functioned as an essential quality assurance tool, enabling the identification of outliers and improving the overall precision of APT analysis.

Conclusion

The proposed DIGITAL method can effectively eliminate fat artifacts and extract accurate APT signals without requiring sequence modifications, offering a promising solution to the long‐standing challenge of lipid contamination in body APT imaging.

Subjects

MeSH terms (MEDLINE)

LipidsMagnetic Resonance ImagingAmidesImage Processing, Computer-AssistedArtifactsPhantoms, ImagingProtonsHumansReproducibility of ResultsAlgorithmsComputer SimulationBreast NeoplasmsFemaleAdipose TissueSignal Processing, Computer-Assisted

Author keywords

Bloch‐McConnell modelamide proton transfer (APT)differential analysis with fitted magnetization transfer and lipid signals (DIG…lipid artifact suppression

Substances

LipidsProtonsAmides

Authors and institutions

  • Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument and Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Z…
  • Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China.
  • MR Collaboration, Siemens Healthcare Ltd., Shanghai, China.

ORCID profiles: Zhechuan Dai, Xingwang Yong, Yi Zhang

Funding

  • National Key Research and Development Program of China
  • Fundamental Research Funds for the Central Universities
  • Zhejiang Provincial Natural Science Foundation of China

Cite

APA

Dai, Z., Wang, X., Yong, X., Zhang, J., Li, Q., Zhang, J., & Zhang, Y. (2026). Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals ( DIGITAL ). Magnetic Resonance in Medicine, 96(2), 756-770. https://doi.org/10.1002/mrm.70384

Vancouver

Dai Z, Wang X, Yong X, Zhang J, Li Q, Zhang J, et al. Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals ( DIGITAL ). Magnetic Resonance in Medicine. 2026;96(2):756-770. doi:10.1002/mrm.70384

BibTeX
@article{Dai2026,
  author = {Dai, Zhechuan and Wang, Xiaoxia and Yong, Xingwang and Zhang, Jing and Li, Qing and Zhang, Jiuquan and Zhang, Yi},
  title = {Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals ( DIGITAL )},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {756--770},
  doi = {10.1002/mrm.70384}
}
Start for free →