EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping

Donovan P Tripp iD, Anne-Sophie van Schelt iD, Omar Darwish iD, Karl P Kunze iD, Shamsa Al Harthy iD, Nader S Metwalli iD, Ahmed M Gharib iD, Claudia Prieto iD, René M Botnar iD, Ralph Sinkus iD, Radhouene Neji iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 682-697

DOI: 10.1002/mrm.70372 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-04-19. Written by Donovan P Tripp and 10 co-authors. Institution: Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Major MEDLINE topics: Elasticity Imaging Techniques, Liver, Imaging, Three-Dimensional, Magnetic Resonance Imaging. 85 references. The full text is freely available (open access, CC BY 4.0). Funded by: EPSRC Centre for Doctoral Training in Smart Medical Imaging, Wellcome EPSRC Centre for Medical Engineering, Siemens Healthineers.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop a sequence for the rapid acquisition of MR elastography (MRE) parameters in 3D, with simultaneous measurement of proton‐density fat fraction (PDFF) and R 2 * for multiparametric assessment of liver disease.

Methods

The proposed sequence uses an interleaved motion‐encoding scheme to acquire 3D volumes of all motion encodings and wave offsets from a single series of readouts with constant repetition time. This leads to a highly time‐efficient acquisition, which together with incoherent k‐space undersampling permits all MRE data to be acquired in a single breathhold. The undersampled volumes are reconstructed using compressed sensing with model‐based temporal regularisation. The sequence can be combined with a multi‐echo readout to allow 3D PDFF and R 2 * maps to be reconstructed from the reference volume of the MRE acquisition. Validation was performed in phantoms and in eight healthy volunteers.

Results

Phantom measurements of all viscoelastic parameters, PDFF, and R 2 * corresponded closely with reference measurements. Average liver tissue parameter values acquired with the combined MRE, PDFF and R 2 * sequence at 3 T were 1.36 0.15 m/s for shear‐wave speed, 1.78 0.41 kPa for the magnitude of the complex shear modulus, 0.70 0.16 kPa for the loss modulus, 3.6% 1.0% for PDFF, and 46.9 7.3 s −1 for R 2 *.

Conclusion

Single‐breathhold 3D MRE in the liver was achieved with a novel acquisition ordering. The sequence offers 3D elastograms from a 16‐s breathhold, or 3D elastograms with co‐registered PDFF and R 2 * maps from a 21‐s breathhold.

Subjects

MeSH terms (MEDLINE)

Elasticity Imaging TechniquesLiverImaging, Three-DimensionalMagnetic Resonance ImagingHumansAdultPhantoms, ImagingFemaleMaleBreath HoldingAlgorithmsReproducibility of ResultsAdipose TissueProtonsImage Interpretation, Computer-AssistedImage Processing, Computer-Assisted

Author keywords

MASLDMR elastographyPDFFR2*liver

Substances

Protons

Authors and institutions

  • Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • MR Application Predevelopment, Siemens Healthcare Limited, Erlangen, Germany.
  • MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
  • National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD, USA.
  • School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
  • Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.

ORCID profiles: Donovan P Tripp, Anne-Sophie van Schelt, Omar Darwish, Karl P Kunze, Shamsa Al Harthy, Nader S Metwalli, Ahmed M Gharib, Claudia Prieto, René M Botnar, Ralph Sinkus, Radhouene Neji

Funding

  • EPSRC Centre for Doctoral Training in Smart Medical Imaging
  • Wellcome EPSRC Centre for Medical Engineering
  • Siemens Healthineers
  • Engineering and Physical Sciences Research Council
  • Center of Interventional Medicine for Precision and Advanced Cellular Therapy
  • National Institute for Health and Care Research
  • Millennium Institute for Intelligent Healthcare Engineering
  • Fondo Nacional de Desarrollo Científico y Tecnológico

Cite

APA

Tripp, D. P., van Schelt, A. S., Darwish, O., Kunze, K. P., Al Harthy, S., Metwalli, N. S., Gharib, A. M., Prieto, C., Botnar, R. M., Sinkus, R., & Neji, R. (2026). Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping. Magnetic Resonance in Medicine, 96(2), 682-697. https://doi.org/10.1002/mrm.70372

Vancouver

Tripp DP, van Schelt AS, Darwish O, Kunze KP, Al Harthy S, Metwalli NS, et al. Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping. Magnetic Resonance in Medicine. 2026;96(2):682-697. doi:10.1002/mrm.70372

BibTeX
@article{Tripp2026,
  author = {Tripp, Donovan P and van Schelt, Anne-Sophie and Darwish, Omar and Kunze, Karl P and Al Harthy, Shamsa and Metwalli, Nader S and Gharib, Ahmed M and Prieto, Claudia and Botnar, René M and Sinkus, Ralph and Neji, Radhouene},
  title = {Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {682--697},
  doi = {10.1002/mrm.70372}
}
Start for free →