EUVIMEDEUVIMED entdecken
Crossref

Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude

Naoki Tano iD, Ren Koda iD, Shunichiro Tanigawa, Naohisa Kamiyama, Yoshiki Yamakoshi, Marie Tabaru

Ultrasonic Imaging · 2024

DOI: 10.1177/01617346241247127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2024. Verfasst von Naoki Tano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Innovative Research, Tokyo Institute of Technology, Yokohama, Japan. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Phantoms, Imaging, Liver, Liver Cirrhosis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study addresses a crucial necessity in the field of noninvasive liver fibrosis diagnosis by introducing the concept of continuous shear wave elastography (C-SWE), utilizing an external vibration source and color Doppler imaging. However, an application of C-SWE to assess liver elasticity, a deep region within the human body, arises an issue of signal instability in the obtained data. To tackle this challenge, this work proposes a method involving the acquisition of multiple frames of datasets, which are subsequently compressed. Furthermore, the proposed frame-to-frame equalization method compensates discrepancies in the initial phase that might exist among multiple-frame datasets, thereby significantly enhancing signal stability. The experimental validation of this approach encompasses both phantom tests and in vivo experiments. In the phantom tests, the proposed technique is validated through a comparison with the established shear wave elastography (SWE) technique. The results demonstrate a remarkable agreement, with an error in shear wave velocity of less than 4.2%. Additionally, the efficacy of the proposed method is confirmed through in vivo tests. As a result, the stabilization of observed shear waves using the frame-to-frame equalization technique exhibits promising potential for accurately assessing human liver elasticity. These findings collectively underscore the viability of C-SWE as a potential diagnostic instrument for liver fibrosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesPhantoms, ImagingLiverLiver CirrhosisHumansReproducibility of ResultsMaleAdultFemale

Stichwörter der Autor:innen

liver fibrosisshear wave elastographytissue elasticity

Autor:innen und Institutionen

  • Institute of Innovative Research, Tokyo Institute of Technology, Yokohama, Japan.
  • Graduate School of Science and Technology, Gunma University, Kiryu, Japan.
  • Ultrasound General Imaging, GE HealthCare, Hino City, Japan.

ORCID-Profile: Naoki Tano, Ren Koda

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Tano, N., Koda, R., Tanigawa, S., Kamiyama, N., Yamakoshi, Y., & Tabaru, M. (2024). Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude. Ultrasonic Imaging. https://doi.org/10.1177/01617346241247127

Vancouver

Tano N, Koda R, Tanigawa S, Kamiyama N, Yamakoshi Y, Tabaru M. Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude. Ultrasonic Imaging. 2024. doi:10.1177/01617346241247127

BibTeX
@article{Tano2024,
  author = {Tano, Naoki and Koda, Ren and Tanigawa, Shunichiro and Kamiyama, Naohisa and Yamakoshi, Yoshiki and Tabaru, Marie},
  title = {Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude},
  journal = {Ultrasonic Imaging},
  year = {2024},
  doi = {10.1177/01617346241247127}
}
Kostenlos starten →